Isotropic 3D fast FLAIR imaging of the brain in multiple sclerosis patients:: initial experience

被引:44
作者
Tan, IL
Pouwels, PJW
van Schijndel, RA
Adèr, HJ
Manoliu, RA
Barkhof, F
机构
[1] Vrije Univ Amsterdam Med Ctr, MR Ctr MS Res, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Radiol, NL-1007 MB Amsterdam, Netherlands
关键词
MR imaging; multiple sclerosis; FLAIR; 3D; image registration;
D O I
10.1007/s00330-001-1170-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The application of image registration and subtraction to detect change in multiple sclerosis (MS) disease burden on serial MR scans benefits from the use of isotropic voxels. An optimised 3D fast fluid-attenuated inversion recovery (FLAIR) sequence with 1.2- and 1.8-mm cubic voxels was compared with a 2D T2 SE sequence using standard 3-mm slices. Three-dimensional fast FLAIR and T2 SE series were obtained in 20 MS patients and 15 controls. Whole brain acquisition times for the 1.2- and 1.8-mm FLAIR were 21 and 10.5 min, respectively. for the interleaved T2 SE 16 min. Brain lesions were marked in consensus by two radiologists and the CNR was calculated in ten lesions. The mean number of lesions detected with the 1.2-mm FLAIR sequence was 115+/-76, compared with 85+/-59 for the T2 SE series (p<0.001). The 1.8-mm FLAIR detected only 73+/-46 lesions. The CNR of the 1.2-mm FLAIR was significantly better than the T2 SE (p<0.01). but not as good as the 1.8-mm FLAIR. In conclusion, isotropic 3D fast FLAIR using 1.2-mm cubic voxels is superior to the 2D T2 SE in the detection of brain lesions in MS patients. The isotropic 1.8-mm FLAIR is faster and has better contrast characteristics but lacks sensitivity.
引用
收藏
页码:559 / 567
页数:9
相关论文
共 21 条
[1]   3D fast FLAIR: A CSF-nulled 3D fast spin-echo pulse sequence [J].
Barker, GJB .
MAGNETIC RESONANCE IMAGING, 1998, 16 (07) :715-720
[2]   Strategies for optimizing MRI techniques aimed at monitoring disease activity in multiple sclerosis treatment trials [J].
Barkhof, F ;
Filippi, M ;
Miller, DH ;
Tofts, P ;
Kappos, L ;
Thompson, AJ .
JOURNAL OF NEUROLOGY, 1997, 244 (02) :76-84
[3]  
Filippi M, 1999, AM J NEURORADIOL, V20, P1931
[4]   Guidelines for using quantitative measures of brain magnetic resonance imaging abnormalities in monitoring the treatment of multiple sclerosis [J].
Filippi, M ;
Horsfield, MA ;
Adèr, HJ ;
Barkhof, F ;
Bruzzi, P ;
Evans, A ;
Frank, JA ;
Grossman, RI ;
McFarland, HF ;
Molyneux, P ;
Paty, DW ;
Simon, J ;
Tofts, PS ;
Wolinsky, JS ;
Miller, DH .
ANNALS OF NEUROLOGY, 1998, 43 (04) :499-506
[5]   Multiple sclerosis lesion detect in the brain: A comparison of fast fluid-attenuated inversion recovery and conventional T2-weighted dual spin echo [J].
GawneCain, ML ;
ORiordan, JI ;
Thompson, AJ ;
Moseley, IF ;
Miller, DH .
NEUROLOGY, 1997, 49 (02) :364-370
[6]   USE OF FLUID ATTENUATED INVERSION RECOVERY (FLAIR) PULSE SEQUENCES IN MRI OF THE BRAIN [J].
HAJNAL, JV ;
BRYANT, DJ ;
KASUBOSKI, L ;
PATTANY, PM ;
DECOENE, B ;
LEWIS, PD ;
PENNOCK, JM ;
OATRIDGE, A ;
YOUNG, IR ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (06) :841-844
[7]   HIGH SIGNAL REGIONS IN NORMAL WHITE MATTER SHOWN BY HEAVILY T2-WEIGHTED CSF NULLED IR SEQUENCES [J].
HAJNAL, JV ;
DECOENE, B ;
LEWIS, PD ;
BAUDOUIN, CJ ;
COWAN, FM ;
PENNOCK, JM ;
YOUNG, IR ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (04) :506-513
[8]   Multimodality image registration by maximization of mutual information [J].
Maes, F ;
Collignon, A ;
Vandermeulen, D ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :187-198
[9]   Technical issues for MRI examination of the posterior fossa [J].
McGowan, JC ;
Patel, RS .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 2000, 172 :S40-S42
[10]   Guidelines for the use of magnetic resonance techniques in monitoring the treatment of multiple sclerosis [J].
Miller, DH ;
Albert, PS ;
Barkhof, F ;
Francis, G ;
Frank, JA ;
Hodgkinson, S ;
Lublin, FD ;
Paty, DW ;
Reingold, SC ;
Simon, J .
ANNALS OF NEUROLOGY, 1996, 39 (01) :6-16