Clinical evaluation of hydroxyapatite-coated titanium plasma-sprayed and titanium plasma-sprayed cylinder dental implants - A preliminary report

被引:30
作者
Jones, JD
Saigusa, M
VanSickels, JE
Tiner, BD
Gardner, WA
机构
[1] UNIV TEXAS,HLTH SCI CTR,DEPT ORAL & MAXILLOFACIAL SURG,SAN ANTONIO,TX 78284
[2] UNIV TEXAS,HLTH SCI CTR,DEPT PROSTHODONT,SAN ANTONIO,TX 78284
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | 1997年 / 84卷 / 02期
关键词
D O I
10.1016/S1079-2104(97)90058-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The purpose of this article was to present the preliminary results of a prospective clinical trial comparing titanium plasma-sprayed Versus hydroxyapatite-coated titanium plasma-sprayed cylinder (press fit) implants in different regions of the mouth. Study design. Sixty-five subjects met the inclusion requirements. Surgery was done in two phases by four experienced surgeons. Implant placement and abutment connection were separated by 3 to 4 months in the mandible, 6 to 7 months in the maxilla. Patients were assigned to either titanium plasma-sprayed or hydroxyapatite-coated implants on the day of surgery. Implant placement was not stratified for the region of the jaws. Outcome assessment was failure (loss) of an implant before or within 3 months of second phase surgery. Results. Three hundred fifty-two implants equally distributed between titanium plasma-sprayed and hydroxyapatite-coated titanium plasma-sprayed implants were placed in four different sites; anterior maxilla, posterior maxilla, anterior mandible, and posterior mandible. There were a total of 15 failures (4.26%). Overall, titanium plasma-sprayed implants showed a higher but not significant failure rate compared with hydroxyapatite-coated implants (p = 0.06). Although not statistically significant, we believe that a smoking history played an important role in the failure of implants. Conclusion, This study suggests that an hydroxyapatite-coating of an implant allows superior initial integration when compared with a titanium plasma-sprayed surface.
引用
收藏
页码:137 / 141
页数:5
相关论文
共 22 条
[1]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[2]   OSSEOINTEGRATED ORAL IMPLANTS - A SWEDISH MULTICENTER STUDY OF 8139 CONSECUTIVELY INSERTED NOBELPHARMA IMPLANTS [J].
ALBREKTSSON, T ;
DAHL, E ;
ENBOM, L ;
ENGEVALL, S ;
ENGQUIST, B ;
ERIKSSON, AR ;
FELDMANN, G ;
FREIBERG, N ;
GLANTZ, PO ;
KJELLMAN, O ;
KRISTERSSON, L ;
KVINT, S ;
KONDELL, PA ;
PALMQUIST, J ;
WERNDAHL, L ;
ASTRAND, P .
JOURNAL OF PERIODONTOLOGY, 1988, 59 (05) :287-296
[3]  
BLOCK M S, 1989, International Journal of Oral and Maxillofacial Implants, V4, P219
[4]  
BLOCK M S, 1992, Dental Clinics of North America, V36, P27
[5]   EVALUATION OF HYDROXYLAPATITE-COATED TITANIUM DENTAL IMPLANTS IN DOGS [J].
BLOCK, MS ;
KENT, JN ;
KAY, JF .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 45 (07) :601-607
[6]  
BUBBUSH CA, 1986, GERODONTICS, V2, P16
[7]   OSSEOINTEGRATION OF TITANIUM IMPLANTS [J].
CARLSSON, L ;
ROSTLUND, T ;
ALBREKTSSON, B ;
ALBREKTSSON, T ;
BRANEMARK, PI .
ACTA ORTHOPAEDICA SCANDINAVICA, 1986, 57 (04) :285-289
[8]  
COOK S, 1992, J ORAL IMPLANTOL, V23, P354
[9]  
COOK SD, 1992, J ORAL IMPLANTOL, V4, P354
[10]  
COTTLANDER M, 1992, INT J ORAL MAXILLOF, V7, P485