Radial distributions and ejection times of molecular ions in an ion trap mass spectrometer: A laser tomography study of effects of ion density and molecular type

被引:40
作者
Cleven, CD
Cooks, RG
Garrett, AW
Nogar, NS
Hemberger, PH
机构
[1] PURDUE UNIV,DEPT CHEM,W LAFAYETTE,IN 47907
[2] LOS ALAMOS NATL LAB,LOS ALAMOS,NM 87545
关键词
D O I
10.1021/jp951667o
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Photodissociation of mass-selected populations of trapped ions is used as a tool to determine the spatial distributions of the ion clouds under a variety of trapping conditions. These ion tomography experiments are performed in both the axial and radial dimensions, and the results show that the ion cloud expands significantly in the radial dimension as the number of trapped ions is increased. This expansion correlates with an increasing error in mass assignment due to delayed ion ejection. Furthermore, both effects appear to be related to the occurrence of compound-dependent (rather than mass/charge ratio-dependent) effects on ion ejection. The molecular ions of nitrobenzene and n-butylbenzene, and the benzoyl cation, examined under fixed conditions using the same number of ions, each displays different mass shifts which correlate with differences in the magnitudes of their radial distributions. These results demonstrate that the spatial distribution of a collection of ions depends on their physicochemical properties. Furthermore, alterations in the geometry of the trap are shown to be a means of controlling the compound-dependent positional distributions as well as the corresponding mass shifts. Ion tomography measurements of the size of the ion clouds are made for all three types of ions as a function of the number of trapped ions. They show that the compound-dependent mass shifts can be eliminated by symmetrically increasing the spacing of the end cap electrodes, a procedure which deliberately increases the positive octapolar field component. The implications of these results for exact mass measurements using ion traps are considered.
引用
收藏
页码:40 / 46
页数:7
相关论文
共 33 条
[1]   ESTIMATION OF THE POLARIZABILITY OF GASEOUS-IONS BY ION-TRAP MASS MEASUREMENTS [J].
BORTOLINI, O ;
CATINELLA, S ;
TRALDI, P .
ORGANIC MASS SPECTROMETRY, 1993, 28 (04) :428-432
[2]  
BORTOLINI O, 1992, ORG MASS SPECTROM, V27, P927
[3]  
BORTOLINI O, 1994, ORG MASS SPECTROM, V29, P1
[4]   MASS SHIFTS DUE TO ION-ION INTERACTIONS IN A QUADRUPOLE ION-TRAP MASS-SPECTROMETER [J].
CLEVEN, CD ;
COX, KA ;
COOKS, RG ;
BIER, ME .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (06) :451-454
[5]   MASS SHIFTS AND LOCAL SPACE-CHARGE EFFECTS OBSERVED IN THE QUADRUPOLE ION-TRAP AT HIGHER RESOLUTION [J].
COX, KA ;
CLEVEN, CD ;
COOKS, RG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 144 (1-2) :47-65
[6]   MATRIX-ASSISTED LASER DESORPTION IONIZATION INSIDE A QUADRUPOLE ION-TRAP DETECTOR CELL [J].
DOROSHENKO, VM ;
CORNISH, TJ ;
COTTER, RJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (12) :753-757
[7]   THE NONLINEAR ION-TRAP .4. MASS-SELECTIVE INSTABILITY SCAN WITH MULTIPOLE SUPERPOSITION [J].
FRANZEN, J .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 125 (2-3) :165-170
[8]  
GUAN S, 1993, J AM SOC MASS SPECTR, V5, P64
[9]   LASER PHOTODISSOCIATION PROBE FOR ION TOMOGRAPHY STUDIES IN A QUADRUPOLE ION-TRAP MASS-SPECTROMETER [J].
HEMBERGER, PH ;
NOGAR, NS ;
WILLIAMS, JD ;
COOKS, RG ;
SYKA, JEP .
CHEMICAL PHYSICS LETTERS, 1992, 191 (05) :405-410
[10]   AN ELONGATED TRAPPED-ION CELL FOR ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY WITH A SUPERCONDUCTING MAGNET [J].
HUNTER, RL ;
SHERMAN, MG ;
MCIVER, RT .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 50 (03) :259-274