Use of a blood substitute to determine instantaneous murine right ventricular thickening with optical coherence tomography

被引:16
作者
Villard, JW
Feldman, MD
Kim, J
Milner, TE
Freeman, GL
机构
[1] Univ Texas, Hlth Sci Ctr, Div Cardiol, Dept Med, San Antonio, TX 78229 USA
[2] Univ Texas, Austin Biomed Engn Program, Austin, TX 78712 USA
关键词
blood substitute; imaging; lasers; myocardium; tomography;
D O I
10.1161/01.CIR.0000014418.99708.86
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-A satisfactory imaging technique to determine regional wall thickening of the murine myocardium is not available. Although cardiovascular imaging with light offers a novel solution, application is problematic because scattering by erythrocytes causes significant optical attenuation. Methods and Results-Optical coherence tomography (OCT) is a technique for detailed resolution imaging of highly scattering biological tissues. To reduce the high level of blood scattering, a method was devised whereby murine blood was replaced with a hemoglobin-based blood substitute. The scattering and absorption properties of in vitro preparations of whole blood and dilutions of blood with a blood substitute were determined with a spectrophotometer and an inverse-adding doubling algorithm. OCT imaging of the same dilutions demonstrated a significant reduction in scattering at a hematocrit <5%. A fiber-optic OCT imaging system was used to image the murine right midventricular free wall before and after isovolumic replacement with blood substitute. Strong light attenuation prevented full thickness imaging before replacement, whereas visualization of the full ventricular thickness was possible after replacement. Baseline and imaging hematocrits were 52.4+/-3.8% and 3.7+/-1.2%, respectively. End-systolic and end-diastolic thickness values were 0.458+/-0.051 mm and 0.352+/-0.047 min. Percent thickening fraction was 30.8+/-7.5%. Conclusion-Optical imaging of the intact beating murine right ventricle was substantially improved by isovolumic blood replacement with a hemoglobin-bused blood substitute. Although the current study has been directed toward imaging the murine heart, a blood substitute may be applied to various optical diagnostic and therapeutic techniques under investigation in cardiovascular medicine.
引用
收藏
页码:1843 / 1849
页数:7
相关论文
共 34 条
  • [1] AN ACCURATE, NONTRAUMATIC ULTRASONIC METHOD TO MONITOR MYOCARDIAL WALL THICKENING IN PATIENTS UNDERGOING CARDIAC-SURGERY
    BOLLI, R
    HARTLEY, CJ
    CHELLY, JE
    PATEL, BS
    RABINOVITZ, RS
    JEROUDI, MO
    ROBERTS, R
    NOON, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (05) : 1055 - 1065
  • [2] Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography
    Boppart, SA
    Tearney, GJ
    Bouma, BE
    Southern, JF
    Brezinski, ME
    Fujimoto, JG
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (09) : 4256 - 4261
  • [3] Brennan JF, 1997, CIRCULATION, V96, P99
  • [4] Brezinski M, 2001, CIRCULATION, V103, P1999
  • [5] Imaging of coronary artery microstructure (in vitro) with optical coherence tomography
    Brezinski, ME
    Tearney, GJ
    Bouma, BE
    Boppart, SA
    Hee, MR
    Swanson, EA
    Southern, JF
    Fujimoto, JG
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (01) : 92 - 93
  • [6] Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography
    Chen, ZP
    Milner, TE
    Srinivas, S
    Wang, XJ
    Malekafzali, A
    vanGemert, MJC
    Nelson, JS
    [J]. OPTICS LETTERS, 1997, 22 (14) : 1119 - 1121
  • [7] Duck F., 1990, Physical Properties of Tissue, P43
  • [8] DUEROS MG, 2001, J OPT SOC AM A, V18, P2945
  • [9] High resolution in vivo intra-arterial imaging with optical coherence tomography
    Fujimoto, JG
    Boppart, SA
    Tearney, GJ
    Bouma, BE
    Pitris, C
    Brezinski, ME
    [J]. HEART, 1999, 82 (02) : 128 - 133
  • [10] HEE MR, 1995, ARCH OPHTHALMOL-CHIC, V113, P326