Effect of intermittent aeration regulation of a multi-soil-layering system on domestic wastewater treatment in Thailand

被引:67
作者
Luanmanee, S
Boonsook, P
Attanandana, T [1 ]
Saitthiti, B
Panichajakul, C
Wakatsuki, T
机构
[1] Kasetsart Univ, Fac Agr, Dept Soil Sci, Bangkok 10900, Thailand
[2] Kasetsart Univ, Dept Farm Mech, Bangkok 10900, Thailand
[3] Kasetsart Univ, Dept Environm Sci, Bangkok 10900, Thailand
[4] Shimane Univ, Fac Life & Environm Sci, Matsue, Shimane, Japan
关键词
multi-soil-layering system; domestic wastewater treatment; aeration; pH regulation; nitrogen removal; phosphorus removal;
D O I
10.1016/S0925-8574(01)00103-3
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
This study investigated the effect of aeration of a multi-soil-layering (MSL) system on domestic wastewater treatment. The MSL system was constructed in a 100 x 200 x 150 cm concrete tank. Clayley soil was mixed with sawdust and iron scraps at a ratio of 75:10:15, respectively, based on dry weight. The soil mixture was filled into the tank as blocks, thus forming a brick-like layer pattern. The void spaces between the soil blocks were filled with zeolite. Combined toilet and cafeteria wastewater, which was pre-treated using settlement tanks, was discharged periodically to the MSL system. The loading rate of wastewater varied from 100 to 600 1 m(-2)d(-1). Aeration was applied to the MSL system at rates of 0.4000 and 20,000 1 m(-1)d(-1). The results revealed that the aeration assists the removal efficiency of biochemical oxygen demand (BOD5), chemical oxygen demand (COD) and soluble reactive phosphorus (SRP). When the MSL system was aerated at a rate of 4000 1 m(-3)d(-1) for 1 week, BOD5, COD and SRP removal efficiencies reached 87.4, 53.2 and 80.3%, respectively. However, at this aeration rate, the efficiency of total nitrogen (TN) removal declined to -26.7%. Aeration at a rate of 20,000 1 m(-3)d(-1) for 3 days was more effective for enhancing BOD5, COD, TN and SRP removals than aeration at the rate of 4000 1 m(-3)d(-1). The removal percentages of BOD5, COD, TN and SRP at values of 92.2, 73.3, 15.0 and 74.7, respectively, were recorded. Two months of non-aeration decreased the COD removal efficiency to <27%, whereas the BOD5, TN and SRP removals were at high levels of 82.1, 65.3, and 83.0%, respectively. This suggested that COD removal needed more intensive aeration than the other parameters. Aeration at a rate of 20,000 1 m(-3)d(-1) alternated with 2 months of non-aeration is appropriate for operating the tested MSL system in Thailand. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:415 / 428
页数:14
相关论文
共 14 条
[1]  
*APHA, 1992, STAND METH EX WAT WA
[2]   Multi-media-layering system for food service wastewater treatment [J].
Attanandana, T ;
Saitthiti, B ;
Thongpae, S ;
Kritapirom, S ;
Luanmanee, S ;
Wakatsuki, T .
ECOLOGICAL ENGINEERING, 2000, 15 (1-2) :133-138
[3]   A MANUAL COLORIMETRIC PROCEDURE FOR MEASURING AMMONIUM NITROGEN IN SOIL AND PLANT KJELDAHL DIGESTS [J].
BAETHGEN, WE ;
ALLEY, MM .
COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1989, 20 (9-10) :961-969
[4]  
Gomez K.A., 1984, Statistical Procedures for Agricultural Research
[5]  
Halling-Sorensen B., 1993, The Removal of Nitrogen Compounds from Wastewater
[6]   CONTROLLED CARBON SOURCE ADDITION TO AN ALTERNATING NITRIFICATION DENITRIFICATION WASTE-WATER TREATMENT PROCESS INCLUDING BIOLOGICAL P-REMOVAL [J].
ISAACS, SH ;
HENZE, M .
WATER RESEARCH, 1995, 29 (01) :77-89
[7]  
Jackson ML., 1958, SOIL CHEM ANAL
[8]  
KADLEC RH, 1996, TREATMENT WETLANDS
[9]   The efficiency of a multi-soil-layering system on domestic wastewater treatment during the ninth and tenth years of operation [J].
Luanmanee, S ;
Attanandana, T ;
Masunaga, T ;
Wakatsuki, T .
ECOLOGICAL ENGINEERING, 2001, 18 (02) :185-199
[10]  
Masunaga T., 1999, P 12 INT C CHEM PROT, P303