Generalized SMASH imaging

被引:93
作者
Bydder, M [1 ]
Larkman, DJ [1 ]
Hajnal, JV [1 ]
机构
[1] Imperial Coll Sch Med, Hammersmith Hosp, MRC, Ctr Clin Sci,Robert Steiner MR Unit, London W12 0HS, England
关键词
magnetic resonance imaging; parallel imaging; array coils; image reconstruction;
D O I
10.1002/mrm.10044
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A generalized parallel imaging method has been developed that uses coil profiles to generate missing k-space lines. The proposed method is an extension of SMASH, which uses linear combinations of coil sensitivity profiles to synthesize spatial harmonics. In the generalized SMASH approach described here, coil sensitivity profiles are represented directly in the Fourier domain to provide a general description of the spatial properties of the coils. This removes restrictions imposed by conventional SMASH, so that the choice and position of the receiver coils can be made on the basis of sensitivity to the volume of interest rather than suitability for constructing spatial harmonics. Generalized SMASH also intrinsically allows the freedom to accommodate acquisitions with uniform or nonuniform k-space sampling. The proposed method places SMASH on an equal footing with other parallel imaging techniques (SENSE and SPACE-RIP), while combining strengths from each. The method was tested on phantom and human data and provides a robust method of data recovery. Magn Reson Med 47:160-170, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:160 / 170
页数:11
相关论文
共 21 条
[1]   VOLUME IMAGING WITH MR PHASED-ARRAYS [J].
HAYES, CE ;
HATTES, N ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :309-319
[2]  
HERLIHY DJ, 2000, P 8 ANN M ISMRM, P1394
[3]   FAST MRI DATA ACQUISITION USING MULTIPLE DETECTORS [J].
HUTCHINSON, M ;
RAFF, U .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (01) :87-91
[4]  
Jakob PM, 1998, MAGN RESON MATER PHY, V7, P42
[5]  
Kyriakos WE, 2000, MAGNET RESON MED, V44, P301, DOI 10.1002/1522-2594(200008)44:2<301::AID-MRM18>3.0.CO
[6]  
2-D
[7]   An investigation into the use of sensitivity-encoded techniques to increase temporal resolution in dynamic contrast-enhanced breast imaging [J].
Larkman, DJ ;
deSouza, NM ;
Bydder, M ;
Hajnal, JV .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :329-335
[8]  
Larkman DJ, 2001, J MAGN RESON IMAGING, V13, P313, DOI 10.1002/1522-2586(200102)13:2<313::AID-JMRI1045>3.3.CO
[9]  
2-N
[10]   A spectral approach to analyzing slice selection in planar imaging: Optimization for through-plane interpolation [J].
Noll, DC ;
Boada, FE ;
Eddy, WF .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) :151-160