The influence of micro-motion on the tissue differentiation around immediately loaded cylindrical turned titanium implants

被引:114
作者
Duyck, J
Vandamme, K
Geris, L
Van Oosterwyck, H
De Cooman, M
Vandersloten, J
Puers, R
Naert, I
机构
[1] Catholic Univ Louvain, Dept Prosthet Dent, BIOMAT Res Grp, B-3000 Louvain, Belgium
[2] Catholic Univ Louvain, Dept Mech Engn, Div Biomech & Engn Design, B-3001 Heverlee, Belgium
[3] Catholic Univ Louvain, Dept Electrotech, ESAT, MICAS, B-3001 Heverlee, Belgium
关键词
animal; bone chamber; titanium; implant; immediate loading;
D O I
10.1016/j.archoralbio.2005.04.003
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Objective: The aim of this study was to evaluate the effect of various degrees of implant displacement on the tissue differentiation around immediately loaded cylindrical turned titanium implants. Design: The experiments were conducted in repeated sampling bone chambers placed in the tibia of 10 rabbits. Tissues could grow into the bone chambers via perforations. Due to its double structure, tissues inside the chamber could be harvested leaving the chamber intact. This allowed several experiments within the same animal. The chambers contained a cylindrical turned titanium implant that was loaded in a well-controlled manner. In each of the 10 chambers, four experiments were conducted with the following test conditions: immediate implant loading by inducing 0 (control), 30, 60 and 90 mu m implant displacement, 800 cycles per day at a frequency of 1 Hz, twice a week during a period of 6 weeks. Histological and histomorphometrical analyses were performed on methylmethacrylate histological sections. An ANOVA was conducted on the dataset. Results: The total tissue volume was significantly lowest in the unloaded control condition. The bone volume fraction on the other hand, was significantly larger in the unloaded and 90 mu m implant displacement, compared to the 30 mu m implant displacement. Bone density increased with increasing micro-motion with significantly higher values for the 60 mu m- and 90 mu m-test conditions compared to the unloaded situation. The chance to have bone-to-implant contact decreased in case of micro-motion at the tissues-implant interface. Conclusion: The magnitude of implant displacement had a statistically significant effect on the tissue differentiation around immediately loaded cylindrical turned titanium implants. Implant micro-motion had a detrimental effect on the bone-to-implant contact in an immediate loading regimen. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 37 条
[1]
OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[2]
ALBREKTSSON T, 1986, DENT CLIN N AM, V30, P151
[3]
Aparicio Carlos, 2003, Clin Implant Dent Relat Res, V5, P57, DOI 10.1111/j.1708-8208.2003.tb00183.x
[4]
BALSHI TJ, 1997, IMPLANTS DENT, V5, P83
[5]
Branemark P I, 1999, Clin Implant Dent Relat Res, V1, P2, DOI 10.1111/j.1708-8208.1999.tb00086.x
[6]
BRANEMARK P I, 1969, Scandinavian Journal of Plastic and Reconstructive Surgery, V3, P81
[7]
Effect of masticatory function on the internal bone structure in the mandible of the growing rat [J].
Bresin, A ;
Kiliaridis, S ;
Strid, KG .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1999, 107 (01) :35-44
[8]
EFFECT OF MOVEMENT ON BONDING OF POROUS METAL TO BONE [J].
CAMERON, HU ;
PILLIAR, RM ;
MACNAB, I .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1973, 7 (04) :301-311
[9]
Cannizzaro G, 2003, INT J ORAL MAX IMPL, V18, P512
[10]
Colomina L E, 2001, Implant Dent, V10, P23