Biomechanical simulation of high-heeled shoe donning and walking

被引:55
作者
Yu, Jia [1 ]
Cheung, Jason Tak-Man [2 ]
Wong, Duo Wai-Chi [1 ]
Cong, Yan [1 ]
Zhang, Ming [1 ]
机构
[1] Hong Kong Polytech Univ, Interdisciplinary Div Biomed Engn, Hong Kong, Hong Kong, Peoples R China
[2] Li Ning Sports Sci Res Ctr, Beijing, Peoples R China
关键词
Finite element analysis; Contact simulation; Foot biomechanics; Footwear design; High heels; FINITE-ELEMENT-ANALYSIS; FOOT; SELECTION; INSOLES; HEIGHT;
D O I
10.1016/j.jbiomech.2013.05.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Footwear serves to protect the foot in various activities, to enhance athletic performance in sports and in many cases to fulfill aesthetic and cultural needs of urban society. Most women like wearing high-heeled shoes (HHS) for the benefit of sensuous attractiveness, while foot problems are often associated. Computational modeling based on finite element (FE) analysis is a useful tool for deep understanding of foot and footwear biomechanics and incorporating footwear with foot in the model is the prerequisite. In this study, a three-dimensional FE model of coupled foot ankle shoe complex and preceding gait simulation were established. Interfacial contact simulation was employed to complete the donning process of foot and shoe upper contact. Three major stance phases namely heel strike, midstance and push off were simulated to investigate the biomechanical response of high-heeled shod walking. It was found that the contact pressure at all metatarsophalangeal (MTP) joints intensified and reached their maximum at push off phase during locomotion, meanwhile the first MTP had the largest magnitude. The first and fifth MTP joints had larger movements in transverse plane among all MTP joints, indicating that these two joints bended more significantly by toe box restraint during locomotion. The dorsal contact pressure at the first toe increased by four times from heel strike to push off. The established HHS donning and walking simulation in this study proved the versatility and promising potential of computational approach for realistic biomechanical evaluation and optimization of footwear design in a virtual environment. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2067 / 2074
页数:8
相关论文
共 33 条
[1]
ABAQUS, 2011, ABAQUS 6 11 MAN
[2]
LUMBAR CURVE, TRUNK MUSCLES, AND LINE OF GRAVITY WITH DIFFERENT HEEL HEIGHTS [J].
BENDIX, T ;
SORENSEN, SS ;
KLAUSEN, K .
SPINE, 1984, 9 (02) :223-227
[3]
Broch N.L., 2004, Journal of the American Podiatric Medical Association, V94, P61
[4]
Effects of total contact insoles on the plantar stress redistribution: a finite element analysis [J].
Chen, WP ;
Ju, CW ;
Tang, FT .
CLINICAL BIOMECHANICS, 2003, 18 (06) :S17-S24
[5]
Parametric design of pressure-relieving foot orthosis using statistics-based finite element method [J].
Cheung, Jason Tak-Man ;
Zhang, Ming .
MEDICAL ENGINEERING & PHYSICS, 2008, 30 (03) :269-277
[6]
Current methods in computer-aided engineering for footwear design [J].
Cheung, Jason Tak-Man ;
Yu, Jia ;
Wong, Duo Wai-Chi ;
Zhang, Ming .
FOOTWEAR SCIENCE, 2009, 1 (01) :31-46
[7]
Three-dimensional finite element analysis of the foot during standing - a material sensitivity study [J].
Cheung, JTM ;
Zhang, M ;
Leung, AKL ;
Fan, YB .
JOURNAL OF BIOMECHANICS, 2005, 38 (05) :1045-1054
[8]
Effect of heel height on in-shoe localized triaxial stresses [J].
Cong, Yan ;
Cheung, Jason Tak-Man ;
Leung, Aaron K. L. ;
Zhang, Ming .
JOURNAL OF BIOMECHANICS, 2011, 44 (12) :2267-2272
[9]
Long-term use of high-heeled shoes alters the neuromechanics of human walking [J].
Cronin, Neil J. ;
Barrett, Rod S. ;
Carty, Christopher P. .
JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (06) :1054-1058
[10]
Dul J., 1983, THESIS VANDERBILT U