Semi-on-line microwave-assisted digestion of shellfish tissue for the determination of selenium by electrothermal atomic absorption spectrometry

被引:24
作者
Arruda, MAZ [1 ]
Gallego, M [1 ]
Valcarcel, M [1 ]
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
关键词
selenium determination; shellfish samples; electrothermal atomic absorption spectrometry; microwave-assisted digestion;
D O I
10.1039/ja9961100169
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrothermal atomic absorption spectrometric method for the determination of selenium in shellfish tissue at the microgram per gram level, following digestion of the sample in a continuous system including a microwave oven, is proposed. In the presence of palladium, the pyrolysis temperature for selenium can be raised to 1100 degrees C, and the signal is increased to a greater extent than with other reported chemical modifiers. The proposed method allows the determination of selenium in the range 25-250 mu g l(-1) (2.5-25 mu g l(-1) Se after 10-fold dilution in the how manifold). The precision achieved, expressed as the relative standard deviation, was 6.8% for within-run assays and 12.5% for between-run assays. The pow system is characterized by its simplicity (no special device is needed to process evolved gases during sample digestion). Samples can be introduced into the system as slurries made from unlyophilised fresh shellfish tissue (there is no difference between the mean results for unlyophilised and lyophilised samples).
引用
收藏
页码:169 / 173
页数:5
相关论文
共 19 条
[1]   WET ASHING OF SOME BIOLOGICAL SAMPLES IN A MICROWAVE OVEN [J].
ABUSAMRA, A ;
MORRIS, JS ;
KOIRTYOHANN, SR .
ANALYTICAL CHEMISTRY, 1975, 47 (08) :1475-1477
[2]   SPECTRAL INTERFERENCES ON THE DETERMINATION OF SELENIUM BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
ALLER, AJ ;
GARCIAOLALLA, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (05) :753-760
[3]  
[Anonymous], 1987, ANALYST, V112, P199
[4]   DETERMINATION OF ALUMINUM IN SLURRY AND LIQUID-PHASE OF JUICES BY FLOW-INJECTION ANALYSIS GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
ARRUDA, MAZ ;
GALLEGO, M ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1993, 65 (22) :3331-3335
[5]   FLOW-THROUGH MICROWAVE DIGESTION SYSTEM FOR THE DETERMINATION OF ALUMINUM IN SHELLFISH BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
ARRUDA, MAZ ;
GALLEGO, M ;
VALCARCEL, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (07) :501-504
[6]   DETERMINATION OF LEAD IN BIOLOGICAL-MATERIALS BY MICROWAVE-ASSISTED MINERALIZATION AND FLOW-INJECTION ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BURGUERA, JL ;
BURGUERA, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :235-241
[7]  
Burguera M., 1993, Laboratory Robotics and Automation, V5, P277
[8]   FLOW-INJECTION AND MICROWAVE-OVEN SAMPLE DECOMPOSITION FOR DETERMINATION OF COPPER, ZINC AND IRON IN WHOLE-BLOOD BY ATOMIC-ABSORPTION SPECTROMETRY [J].
BURGUERA, M ;
BURGUERA, JL ;
ALARCON, OM .
ANALYTICA CHIMICA ACTA, 1986, 179 :351-357
[9]   DETERMINATION OF LEAD IN WINE, OTHER BEVERAGES AND FRUIT SLURRIES BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY WITH ONLINE MICROWAVE DIGESTION [J].
CABRERA, C ;
MADRID, Y ;
CAMARA, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (12) :1423-1426
[10]   ATOMIC-ABSORPTION SPECTROMETRIC ANALYSIS OF SOLIDS WITH ONLINE MICROWAVE-ASSISTED DIGESTION [J].
CARBONELL, V ;
MORALESRUBIO, A ;
SALVADOR, A ;
DELAGUARDIA, M ;
BURGUERA, JL ;
BURGUERA, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (07) :1085-1089