The effect of ablation electrode length and catheter tip to endocardial orientation on radiofrequency lesion size in the canine right atrium

被引:34
作者
Chan, RC [1 ]
Johnson, SB [1 ]
Seward, JB [1 ]
Packer, DL [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Internal Med, Div Cardiol, Rochester, MN 55905 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2002年 / 25卷 / 01期
关键词
radiofrequency ablation; intracardiac ultrasound; atrium; atrial fibrillation;
D O I
10.1046/j.1460-9592.2002.00004.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although the determinants of radiofrequency lesion size have been characterized in vitro and in ventricular tissue in situ, the effects of catheter tip length and endocardial surface orientation on lesion generation in atrial tissue have not been studied. Therefore, the dimensions of radiofrequency lesions produced with 4-, 6-, 8-, 10-, and 12-mm distal electrode lengths were characterized in 26 closed-chested dogs. The impact of parallel versus perpendicular catheter tip/endocardial surface orientation, established by biplane fluoroscopy and/or intracardiac echocardiography, on lesion dimensions was also assessed, Radiofrequency voltage;vas titrated to maintain a steady catheter tip temperature of 75degreesC for 60 seconds. With a perpendicular catheter tip/tissue orientation, the lesion area increased from 29 +/- 7 mm(2) with a 4-mm tip to 42 +/- 12 mm(2) with the 10-mm tip, but decreased to 29 +/- 8 mm(2) with ablation via a 12-mm tip. With a parallel distal tip/endocardial surface orientation, lesion areas were significantly greater: 54 +/- 22 mm(2) with a 4-mm tip, 96 +/- 28 mm(2) with a 10-mm tip and 68 +/- 24 mm(2) with a 12-mm tip (all P < 0.001 vs perpendicular orientation). Lesion lengths and apparent volumes were larger with parallel, compared to perpendicular tip/tissue orientations, although lesion depth vas independent of catheter tip length with both catheter tip/tissue orientations. Electrode edge effects were not observed;with any tip length. Direct visualization using intracardiac ultrasound guidance was subjectively helpful in insuring an appropriate catheter tip/tissue interface needed to maximize lesion size. Although atrial lesion size is critically dependent on catheter tip length, it is more influenced by the catheter orientation to the endocardial surface. This information may also be helpful in designing electrode arrays for the creation of continuous linear lesions for the elimination of complex atrial tachyarrhythmias.
引用
收藏
页码:4 / 13
页数:10
相关论文
共 30 条
[1]  
[Anonymous], 1986, J APPL CARDIOL
[2]   THE EFFECT OF ELECTRODE DESIGN ON THE EFFICIENCY OF DELIVERY OF RADIOFREQUENCY ENERGY TO CARDIAC TISSUE INVITRO [J].
BLOUIN, LT ;
MARCUS, FI .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (01) :136-143
[3]  
CHAN RC, 1995, PACE PACING CLIN ELE, V18, P856
[4]  
CHAN RC, 1995, J AM COLL CARDIOL, V25, pA41
[5]   RADIOFREQUENCY CATHETER ABLATION OF THE ATRIA REDUCES INDUCIBILITY AND DURATION OF ATRIAL-FIBRILLATION IN DOGS [J].
ELVAN, A ;
PRIDE, HP ;
EBLE, JN ;
ZIPES, DP .
CIRCULATION, 1995, 91 (08) :2235-2244
[6]   RADIOFREQUENCY CATHETER ABLATION FOR THE TREATMENT OF HUMAN TYPE-1 ATRIAL-FLUTTER - IDENTIFICATION OF A CRITICAL ZONE IN THE REENTRANT CIRCUIT BY ENDOCARDIAL MAPPING TECHNIQUES [J].
FELD, GK ;
FLECK, RP ;
CHEN, PS ;
BOYCE, K ;
BAHNSON, TD ;
STEIN, JB ;
CALISI, CM ;
IBARRA, M .
CIRCULATION, 1992, 86 (04) :1233-1240
[7]   RADIOFREQUENCY CATHETER ABLATION OF COMMON ATRIAL-FLUTTER IN 80 PATIENTS [J].
FISCHER, B ;
HAISSAGUERRE, M ;
GARRIGUES, S ;
POQUET, F ;
GENCEL, L ;
CLEMENTY, J ;
MARCUS, FI .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (06) :1365-1372
[8]   ELECTRODE RADIUS PREDICTS LESION RADIUS DURING RADIOFREQUENCY ENERGY HEATING - VALIDATION OF A PROPOSED THERMODYNAMIC MODEL [J].
HAINES, DE ;
WATSON, DD ;
VEROW, AF .
CIRCULATION RESEARCH, 1990, 67 (01) :124-129
[9]   OBSERVATIONS ON ELECTRODE-TISSUE INTERFACE TEMPERATURE AND EFFECT ON ELECTRICAL-IMPEDANCE DURING RADIOFREQUENCY ABLATION OF VENTRICULAR MYOCARDIUM [J].
HAINES, DE ;
VEROW, AF .
CIRCULATION, 1990, 82 (03) :1034-1038
[10]   TISSUE HEATING DURING RADIOFREQUENCY CATHETER ABLATION - A THERMODYNAMIC MODEL AND OBSERVATIONS IN ISOLATED PERFUSED AND SUPERFUSED CANINE RIGHT VENTRICULAR FREE WALL [J].
HAINES, DE ;
WATSON, DD .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (06) :962-976