Piezoelectric immunosensors for urine specimens of Chlamydia trachomatis employing quartz crystal microbalance microgravimetric analyses

被引:102
作者
BenDov, I
Willner, I
Zisman, E
机构
[1] HEBREW UNIV JERUSALEM,INST CHEM,IL-91904 JERUSALEM,ISRAEL
[2] SAVYON DIAGNOST LTD,IL-77101 ASHDOD,ISRAEL
关键词
D O I
10.1021/ac970216s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The assembly of a biosensor for Chlamydia trachomatis based on the microgravimetric quartz crystal microbalance (QCM) analysis of the bacteria association to an antibody-functionalized electrode is described, The sensing interfaces consist of a primary cystamine monolayer assembled onto Au electrodes associated with the quartz crystal. The monolayer is further modified with sulfosuccinylimidyl 4-(p-maleimidophenyl)butyrate (sulfo-SMPB) and the goat IgG-anti-mouse IgG Fc-specific Ab or the fragmented F(ab')(2) anti-mouse IgG Ab that act as sublayers for the association of the sensor-active anti-C. trachomatis LPS-Ab. Bacteria in the concentration range from 260 ng.mL(-1) to 7.8 mu g.mL(-1) are sensed by the functionalized crystals. The association of C. trachomatis to the sensing interface can be confirmed and amplified via interaction of the crystal with various anti-C. trachomatis antibodies, Urine-pretreated functionalized quartz crystals are applied in the analysis of C. trachomatis in urine samples. The sensitivity limits of the electrodes for sensing the bacteria in urine samples corresponds to similar to 260 ng.mL(-1). The functionalized crystals assembled via association of anti-C. trachomatis LPS-Ab to the fragmented F(ab')(2) anti-mouse IgG Ab reveal long-term stability upon storage at 4 degrees C.
引用
收藏
页码:3506 / 3512
页数:7
相关论文
共 35 条
  • [1] AIZAWA M, 1987, ELECTROCHEMICAL SENS, P269
  • [2] BASTIAANS GJ, 1988, Patent No. 4735906
  • [3] Application of redox enzymes for probing the antigen-antibody association at monolayer interfaces: Development of amperometric immunosensor electrodes
    Blonder, R
    Katz, E
    Cohen, Y
    Itzhak, N
    Riklin, A
    Willner, I
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (18) : 3151 - 3157
  • [4] THE DEVELOPMENT OF REDOX-MODIFIED ELECTRODES AS CHARGE-ACCUMULATING DEVICES FOR USE IN HIGHER SENSITIVITY DETECTION SYSTEMS
    CHAMBERS, JA
    WALTON, NJ
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 250 (02): : 417 - 425
  • [5] Modified monolayer electrodes for electrochemical and piezoelectric analysis of substrate-receptor interactions: Novel immunosensor electrodes
    Cohen, Y
    Levi, S
    Rubin, S
    Willner, I
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 417 (1-2) : 65 - 75
  • [6] USE OF SCANNING PROBE MICROSCOPY AND SURFACE-PLASMON RESONANCE AS ANALYTICAL TOOLS IN THE STUDY OF ANTIBODY-COATED MICROTITER WELLS
    DAVIES, J
    ROBERTS, CJ
    DAWKES, AC
    SEFTON, J
    EDWARDS, JC
    GLASBEY, TO
    HAYMES, AG
    DAVIES, MC
    JACKSON, DE
    LOMAS, M
    SHAKESHEFF, KM
    TENDLER, SJB
    WILKINS, MJ
    WILLIAMS, PM
    [J]. LANGMUIR, 1994, 10 (08) : 2654 - 2661
  • [7] HOMOGENEOUS FERROCENE-MEDIATED AMPEROMETRIC IMMUNOASSAY
    DIGLERIA, K
    HILL, HAO
    MCNEIL, CJ
    GREEN, MJ
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (06) : 1203 - 1205
  • [8] HOMOGENEOUS AMPEROMETRIC LIGAND-BINDING ASSAY AMPLIFIED BY A PROTEOLYTIC-ENZYME CASCADE
    DIGLERIA, K
    HILL, HAO
    CHAMBERS, JA
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 267 (1-2): : 83 - 91
  • [9] DOYL JM, 1987, ELECTROCHEMICAL SENS, P87
  • [10] GEBAUER CR, 1987, ELECTROCHEMICAL SENS, P239