Fabrication and testing of a miniature H2/O2 and MeOH/O2 fuel cell

被引:6
作者
Apblett, Christopher
Ingersoll, David
Atanassov, Plamen
Maricle, Donald
Sarangapani, S.
机构
[1] Sandia Natl Labs, Albuquerque, NM 87185 USA
[2] Univ New Mexico, Albuquerque, NM 87131 USA
[3] Maricle Consulting LLC, Glastonbury, CT 06033 USA
[4] ICET Inc, Norwood, MA 02062 USA
关键词
hydrogen; methanol; miniature; fuel cell;
D O I
10.1016/j.jpowsour.2006.06.052
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The construction and performance of a small-scale fuel cell using traditional catalysts and membrane separators is discussed. Cell active area was 1 cm x 1 cm, with a total unit cell volume of 0.3 cm(3) each. Under well-hydrated conditions running under hydrogen and oxygen, these cells demonstrated over 600 mW cm(-2) at 80 degrees C. Design of flow fields and the requirements for water management showed that flow channels that were too small may have resulted in early channel blockage on the cathode, leading to lower power. Miniature cells suffered from higher than expected interfacial resistance which increased with time and this may be due either to more difficult hydration control in the membrane at smaller dimensions, or less compression in the smaller scale size leading to higher flow field/diffusion layer interfacial resistances. Running single cells in methanol to alleviate hydration issues still showed much higher interfacial resistances, but cell performance was roughly 75 mW cm(-2) at 80 degrees C in 1M MeOH with 20 sccm of ambient pressure air, and 140 MW cm(-2) in 1M MeOH with 20 sccm ambient pressure O-2. Lower performance in MeOH may be attributed to swelling of the sealing gaskets in methanol, leading to increased interfacial resistances over time. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:255 / 261
页数:7
相关论文
共 27 条
[1]   Influence of flow field design on the performance of a direct methanol fuel cell [J].
Aricò, AS ;
Cretì, P ;
Baglio, V ;
Modica, E ;
Antonucci, V .
JOURNAL OF POWER SOURCES, 2000, 91 (02) :202-209
[2]   Status of the development of a direct methanol fuel cell [J].
Baldauf, M ;
Preidel, W .
JOURNAL OF POWER SOURCES, 1999, 84 (02) :161-166
[3]   Modelling of polymer electrolyte membrane fuel cells with variable degrees of water flooding [J].
Baschuk, JJ ;
Li, XH .
JOURNAL OF POWER SOURCES, 2000, 86 (1-2) :181-196
[4]   Water management in PEM fuel cells [J].
Berg, P ;
Promislow, K ;
St Pierre, J ;
Stumper, J ;
Wetton, B .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2004, 151 (03) :A341-A353
[5]   Membraneless laminar flow-based micro fuel cells operating in alkaline, acidic, and acidic/alkaline media [J].
Choban, ER ;
Spendelow, JS ;
Gancs, L ;
Wieckowski, A ;
Kenis, PJA .
ELECTROCHIMICA ACTA, 2005, 50 (27) :5390-5398
[6]   Real-time water distribution in a polymer electrolyte fuel cell [J].
Dong, Q ;
Kull, J ;
Mench, MM .
JOURNAL OF POWER SOURCES, 2005, 139 (1-2) :106-114
[7]   Membraneless vanadium redox fuel cell using laminar flow [J].
Ferrigno, R ;
Stroock, AD ;
Clark, TD ;
Mayer, M ;
Whitesides, GM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (44) :12930-12931
[8]   Dependence of PEM fuel cell performance on catalyst loading [J].
Gasteiger, HA ;
Panels, JE ;
Yan, SG .
JOURNAL OF POWER SOURCES, 2004, 127 (1-2) :162-171
[9]   Permeation of methanol/methyl-t-butyl ether mixtures through poly (ethylene-co-vinyl acetate) films [J].
Gozzelino, G ;
Malucelli, G .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2004, 235 (1-3) :35-44
[10]   Study of external humidification method in proton exchange membrane fuel cell [J].
Hyun, D ;
Kim, J .
JOURNAL OF POWER SOURCES, 2004, 126 (1-2) :98-103