Controlling the cold collision shift in high precision atomic interferometry

被引:94
作者
Dos Santos, FP
Marion, H
Bize, S
Sortais, Y
Clairon, A
Salomon, C
机构
[1] Observ Paris, BNM, SYRTE, F-75014 Paris, France
[2] ENS, Lab Kastler Brossel, F-75005 Paris, France
关键词
D O I
10.1103/PhysRevLett.89.233004
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We present a new method based on a transfer of population by adiabatic passage that allows one to prepare cold atomic samples with a well-defined ratio of atomic density and atom number. This method is used to perform a measurement of the cold collision frequency shift in a laser cooled cesium clock at the percent level, which makes the evaluation of the cesium fountain accuracy at the 10(-16) level realistic. With improvements, the adiabatic passage would allow measurements of density-dependent phase shifts at the 10(-3) level in high precision experiments.
引用
收藏
页码:1 / 233004
页数:4
相关论文
共 16 条
[1]   ROLE OF COLLISIONS IN THE SEARCH FOR AN ELECTRON ELECTRIC-DIPOLE MOMENT [J].
BIJLSMA, M ;
VERHAAR, BJ ;
HEINZEN, DJ .
PHYSICAL REVIEW A, 1994, 49 (06) :R4285-R4288
[2]   High-accuracy measurement of the 87Rb ground-state hyperfine splitting in an atomic fountain [J].
Bize, S ;
Sortais, Y ;
Santos, MS ;
Mandache, C ;
Clairon, A ;
Salomon, C .
EUROPHYSICS LETTERS, 1999, 45 (05) :558-564
[3]   Cavity frequency pulling in cold atom fountains [J].
Bize, S ;
Sortais, Y ;
Mandache, C ;
Clairon, A ;
Salomon, C .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) :503-506
[4]  
BIZE S, 2001, P 6 S FREQ STAND MET, P53
[5]   Measurement of an electron's electric dipole moment using Cs atoms trapped in optical lattices [J].
Chin, C ;
Leiber, V ;
Vuletic, V ;
Kerman, AJ ;
Chu, S .
PHYSICAL REVIEW A, 2001, 63 (03) :1-8
[6]   Measurement and cancellation of the cold collision frequency shift in an 87Rb fountain clock [J].
Fertig, C ;
Gibble, K .
PHYSICAL REVIEW LETTERS, 2000, 85 (08) :1622-1625
[7]   An experimental study of the spin-exchange frequency shift in a laser-cooled cesium fountain frequency standard [J].
Ghezali, S ;
Laurent, P ;
Lea, SN ;
Clairon, A .
EUROPHYSICS LETTERS, 1996, 36 (01) :25-30
[8]   LASER-COOLED CS FREQUENCY STANDARD AND A MEASUREMENT OF THE FREQUENCY-SHIFT DUE TO ULTRACOLD COLLISIONS [J].
GIBBLE, K ;
CHU, S .
PHYSICAL REVIEW LETTERS, 1993, 70 (12) :1771-1774
[9]   LASER COOLING BELOW A PHOTON RECOIL WITH 3-LEVEL ATOMS [J].
KASEVICH, M ;
CHU, S .
PHYSICAL REVIEW LETTERS, 1992, 69 (12) :1741-1744
[10]  
Lemonde P, 2000, TOP APPL PHYS, V79, P131