Detection of microsatellite instability by real time PCR and hybridization probe melting point analysis

被引:25
作者
Dietmaier, W
Hofstädter, F
机构
[1] Univ Regensburg, Mol Pathol Diagnost Unit, D-93053 Regensburg, Germany
[2] Univ Regensburg, Inst Pathol, D-93053 Regensburg, Germany
关键词
D O I
10.1038/labinvest.3780358
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Microsatellite alterations can be found in a number of tumors. There are two types of alterations: loss of heterozygosity (LOH), which can be detected in the majority of colorectal cancers (CRC), and microsatellite instability (MSI). MSI occurs in about 15% of CRC with a mutator phenotype and are the hallmark of hereditary nonpolyposis colorectal cancers (HNPCC). Furthermore, MSI can also be detected in other tumors which are part of the HNPCC tumor spectrum (eg, gastric, ovarian, and endometrial carcinomas). Usually, a set of microsatellite markers is amplified by PCR followed by gel or capillary electrophoresis to separate PCR amplicons and by detection of the markers using autoradiography (Thibodeau et al, 1993), silver staining (Schlegel et al, 1996), or fluorescence techniques (Gyapay et al, 1996; Mansfield et al, 1994). We have established a technique to detect MSI by LightCycler PCR and melting point analysis using sequence-specific hybridization probes (HyProbes) labeled with LightCycler dyes, LCRed640 and LCRed705. Amplification of microsatellites by real-time PCR is followed by melting point analysis to display alterations in the length of repetitive sequences, thereby avoiding any electrophoretical separation of amplified DNA. Two mononucleotide markers (BAT25 and BAT26) were tested in 81 formalin-fixed and paraffin-embedded colorectal cancer samples with matched normal tissues from 21 MSI tumors and 60 tumors with microsatellite stability. Amplification and melting point determination of BAT26 and BAT25 was possible in 129/162 (80%) and 123/162 (76%) formalin-fixed and paraffin-embedded tissue samples, respectively. MSI could be detected specifically with both BAT25 and BAT26 markers only in MSI-high tumors (greater than or equal to 40% MSI rate, determined with microsatellite reference panel, BAT25, BAT26, D5S346, D2S123, D17S250; Boland et al, 1998; Dietmaier et al, 1997). This new technique allows MSI detection within less than a hour and provides a basis for fast, high-throughput MSI analysis.
引用
收藏
页码:1453 / 1456
页数:4
相关论文
共 10 条
[1]  
Boland CR, 1998, CANCER RES, V58, P5248
[2]  
Cravo M, 1999, J PATHOL, V188, P252, DOI 10.1002/(SICI)1096-9896(199907)188:3<252::AID-PATH354>3.0.CO
[3]  
2-3
[4]  
Dietmaier W, 1997, CANCER RES, V57, P4749
[5]  
Gyapay Gabor, 1996, Methods (Orlando), V9, P91, DOI 10.1006/meth.1996.0012
[6]  
Hoang JM, 1997, CANCER RES, V57, P300
[7]  
Loukola A, 2001, CANCER RES, V61, P4545
[8]   AUTOMATION OF GENETIC-LINKAGE ANALYSIS USING FLUORESCENT MICROSATELLITE MARKERS [J].
MANSFIELD, DC ;
BROWN, AF ;
GREEN, DK ;
CAROTHERS, AD ;
MORRIS, SW ;
EVANS, HJ ;
WRIGHT, AF .
GENOMICS, 1994, 24 (02) :225-233
[9]  
Schlegel J, 1996, BIOTECHNIQUES, V20, P178
[10]   MICROSATELLITE INSTABILITY IN CANCER OF THE PROXIMAL COLON [J].
THIBODEAU, SN ;
BREN, G ;
SCHAID, D .
SCIENCE, 1993, 260 (5109) :816-819