A method for accurate measurement of GFR in conscious, spontaneously voiding rats

被引:15
作者
deVries, PAM
Navis, G
deBoer, E
deJong, PE
deZeeuw, D
Kluppel, CA
机构
[1] GRONINGEN INST DRUG STUDIES,GRONINGEN,NETHERLANDS
[2] UNIV GRONINGEN HOSP,DEPT INTERNAL MED,DIV NEPHROL,GRONINGEN,NETHERLANDS
关键词
renal function; conscious rats; spontaneous voiding;
D O I
10.1038/ki.1997.327
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Renal function measurement by clearance methods relies on accurately timed urine collection. In small experimental animals, renal function measurement is usually performed under anesthesia and/or with the application of bladder catheters to ensure accurate urine collection. To avoid both anesthesia and the need for bladder catheters we developed a method to measure glomerular filtration rate (GFR) in spontaneously voiding conscious rats. GFR was measured as the urinary clearance of constantly infused I-125-iothalamate. To correct for incomplete bladder emptying, urinary clearance of I-125-iothalamate was multiplied by the ratio of plasma and urinary clearance of simultaneously infused I-131-hippuran, a correction method that has been previously validated in humans. Reproducibility of the technique was evaluated by analysis of the results of four consecutive clearance periods during the day (intra-assay variation) in a group of 17 rats and of two consecutive clearance periods on two or three separate days in a group of 20 rats (inter-assay variation), all with normal renal function. Application of the correction method reduced the intra-assay coefficient of variation (mean +/- SD) from 37.4 +/- 14.3 to 5.4 +/- 2.3% (P < 0.05). The mean inter-assay coefficient of variation fell slightly from 23.4 +/- 10.3 to 11.0 +/- 7.2% (P < 0.10). In rats with moderately impaired renal function (N = 8) the intra-assay variation fell from 27.9 +/- 20.7 to 2.7 +/- 1.6% (P < 0.05). Our data show that this correction method is a useful technique to assess renal function in conscious, spontaneously voiding rats.
引用
收藏
页码:244 / 247
页数:4
相关论文
共 20 条
[1]  
Apperloo AJ, 1996, J AM SOC NEPHROL, V7, P567
[2]   NON-INVASIVE METHODS FOR THE MEASUREMENT OF TOTAL RENAL-FUNCTION [J].
BIANCHI, C ;
DONADIO, C ;
TRAMONTI, G .
NEPHRON, 1981, 28 (02) :53-57
[3]  
CHAMBERLAIN RM, 1993, J PHYSL, V473, P270
[4]  
CHAPMAN BJ, 1980, J PHYSL, V305, P8
[5]  
DONKER AJM, 1977, NETH J MED, V20, P97
[6]   CRYSTAL ADHERENCE TO URINARY CATHETER MATERIALS IN RATS [J].
FUSE, H ;
OHKAWA, M ;
NAKASHIMA, T ;
TOKUNAGA, S .
JOURNAL OF UROLOGY, 1994, 151 (06) :1703-1706
[7]   CHRONIC VASCULAR CONSTRICTIONS AND MEASUREMENTS OF RENAL-FUNCTION IN CONSCIOUS RATS [J].
GELLAI, M ;
VALTIN, H .
KIDNEY INTERNATIONAL, 1979, 15 (04) :419-426
[8]  
HORST PJ, 1988, RENAL PHYSIOL BIOCH, V11, P325
[9]   MEASUREMENT OF GLOMERULAR-FILTRATION RATE IN CONSCIOUS UNRESTRAINED RATS WITH INULIN INFUSED BY IMPLANTED OSMOTIC PUMPS [J].
JOBIN, J ;
BONJOUR, JP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1985, 248 (05) :F734-F738
[10]   RENAL-FUNCTION IN RATS WITH INNERVATED AND DENERVATED KIDNEYS BEFORE AND DURING SODIUM PENTOBARBITAL-ANESTHESIA [J].
MERCER, PF ;
KLINE, RL .
CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1984, 62 (06) :683-688