Real-time electrochemical detection of pathogen DNA using electrostatic interaction of a redox probe

被引:85
作者
Ahmed, Minhaz Uddin [1 ,2 ]
Nahar, Sharifun [1 ]
Safavieh, Mohammadali [1 ]
Zourob, Mohammed [1 ,3 ]
机构
[1] INRS, Varennes, PQ J3X 1S2, Canada
[2] Univ Brunei Darussalam, Fac Sci, Gadong 1410, BE, Brunei
[3] King Saud Univ, King Abdulla Inst Nanotechnol, Riyadh 11451, Saudi Arabia
基金
加拿大自然科学与工程研究理事会;
关键词
MEDIATED ISOTHERMAL AMPLIFICATION; METHYLENE-BLUE; CHRONOCOULOMETRIC DNA; PCR; SENSOR; QUANTIFICATION; DIAGNOSTICS; COMPLEXES; BINDING;
D O I
10.1039/c2an36153a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrostatic redox probes interaction has been widely rendered for DNA quantification. We have established a proof-of-principle by using the ruthenium hexaamine molecule [Ru(NH3)(6)](3+). We have applied this method for real-time electrochemical monitoring of a loop mediated isothermal amplification (LAMP) amplicon of target genes of Escherichia coli and Staphylococcus aureus by square wave voltammetry (SWV). Ruthenium hexaamine interaction with free DNAs in solution without being immobilized onto the biochip surface enabled us to discard the time-consuming overnight probe immobilization step in DNA quantification. We have measured the changes in the cathodic current signals using screen printed low-cost biochips both in the presence and the absence of LAMP amplicons of target DNAs in the solution-phase. By using this novel probe, we successfully carried out the real-time isothermal amplification and detection in less than 30 min for S. aureus and E. coli with a sensitivity up to 30 copies mu L-1 and 20 copies mu L-1, respectively. The cathode peak height of the current was related to the extent of amplicon formation and the amount of introduced template genomic DNA. Importantly, since laborious probe immobilization is not necessary at all, and both the in vitro amplification and real-time monitoring are performed in a single polypropylene tube using a single biochip, this novel approach could avoid all potential cross-contamination in the whole procedure.
引用
收藏
页码:907 / 915
页数:9
相关论文
共 50 条
[1]  
Ahmed M. U., 2009, FOOD CONTROL, P599
[2]   Electrochemical DNA biosensor using a disposable electrochemical printed (DEP) chip for the detection of SNPs from unpurified PCR amplicons [J].
Ahmed, Minhaz Uddin ;
Idegami, Koutarou ;
Chikae, Miyuki ;
Kerman, Kagan ;
Chaumpluk, Piyasak ;
Yamamura, Shohei ;
Tamiya, Eiichi .
ANALYST, 2007, 132 (05) :431-438
[3]   Electrochemical genosensor for the rapid detection of GMO using loop-mediated isothermal amplification [J].
Ahmed, Minhaz Uddin ;
Saito, Masato ;
Hossain, M. Mosharraf ;
Rao, S. Ramachandara ;
Furui, Satoshi ;
Hino, Akihiro ;
Takamura, Yuzuru ;
Takagi, Masahiro ;
Tamiya, Eiichi .
ANALYST, 2009, 134 (05) :966-972
[4]   A novel and more sensitive loop-mediated isothermal amplification assay targeting IS6110 for detection of Mycobacterium tuberculosis complex [J].
Aryan, Ehsan ;
Makvandi, Manoochehr ;
Farajzadeh, Ahmad ;
Huygen, Kris ;
Bifani, Pablo ;
Mousavi, Seyed-Latif ;
Fateh, Abolfazl ;
Jelodar, Abbass ;
Gouya, Mohammad-Mehdi ;
Romano, Marta .
MICROBIOLOGICAL RESEARCH, 2010, 165 (03) :211-220
[5]   Miniaturized isothermal nucleic acid amplification, a review [J].
Asiello, Peter J. ;
Baeumner, Antje J. .
LAB ON A CHIP, 2011, 11 (08) :1420-1430
[6]   COMPLEXATION OF HETEROCYCLIC LIGANDS WITH DNA IN AQUEOUS SOLUTION [J].
Baranovskii, S. F. ;
Bolotin, P. A. ;
Evstigneev, M. P. ;
Chernyshev, D. N. .
JOURNAL OF APPLIED SPECTROSCOPY, 2008, 75 (02) :251-260
[7]   DNA Electrochemistry as a probe of base pair stacking in A-, B-, and Z-form DNA [J].
Boon, EM ;
Barton, JK .
BIOCONJUGATE CHEMISTRY, 2003, 14 (06) :1140-1147
[8]   VOLTAMMETRIC STUDIES OF THE INTERACTION OF METAL-CHELATES WITH DNA .2. TRIS-CHELATED COMPLEXES OF COBALT(III) AND IRON(II) WITH 1,10-PHENANTHROLINE AND 2,2'-BIPYRIDINE [J].
CARTER, MT ;
RODRIGUEZ, M ;
BARD, AJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (24) :8901-8911
[9]   Electrochemical sensing of DNA using gold nanoparticles [J].
Castaneda, M. T. ;
Alegret, S. ;
Merkoci, A. .
ELECTROANALYSIS, 2007, 19 (7-8) :743-753
[10]  
Craw P, 2012, LAB CHIP, V12, P2469, DOI [10.1039/c21c40100b, 10.1039/c2lc40100b]