Effects of rod stiffness and fusion mass on the adjacent segments after floating mono-segmental fusion: a study using finite element analysis

被引:39
作者
Jin, Yong Jun [1 ]
Kim, Young Eun [2 ]
Seo, Jung Ho [2 ]
Choi, Hae Won [2 ]
Jahng, Tae-Ahn [3 ]
机构
[1] Inje Univ, Coll Med, Seoul Paik Hosp, Dept Neurosurg, Seoul, South Korea
[2] Dankook Univ, Dept Mech Engn, Yongin 448701, Gyeonggi Do, South Korea
[3] Seoul Natl Univ, Coll Med, Bundang Hosp, Spine Ctr,Dept Neurosurg, Songnam, South Korea
基金
新加坡国家研究基金会;
关键词
Adjacent segment degeneration; Finite element analysis; Rod stiffness; Amount of fusion mass; LUMBAR INTERBODY FUSION; INTRADISCAL PRESSURE; DISK DEGENERATION; SPINE; FIXATION; LEVEL; SPONDYLOLISTHESIS; INSTRUMENTATION; ARTHRODESIS; SURGERY;
D O I
10.1007/s00586-012-2611-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Purpose The aims of the present study were to compare the biomechanical effects on the adjacent segments after mono-segmental floating fusion with posterior semi-rigid or rigid stabilization, and to evaluate the effect of the amount of fusion mass on the biomechanical differences. Methods A detailed, nonlinear L1-S1 finite element model had been developed and validated. Then five models were reconstructed by different fixation techniques on the L3-L4 level: rigid fixation with an interbody spacer (Ti + IS), rigid fixation with a large interbody spacer (Ti + IS_all), semi-rigid fixation with an interbody spacer (PEEK + IS), semi-rigid fixation with a large interbody spacer (PEEK + IS_all), and semi-rigid fixation only (PEEK). Analyses were conducted for the case of erect standing position, flexion, and extension motion. Results At L1-L2 and L2-L3, PEEK + IS demonstrated less inter-segmental rotation and nucleus pressure increments from the intact model compared with Ti + IS. The L4-L5 and L5-S1 levels showed slightly higher values with PEEK + IS, but these differences among the instrumented models were not significant. The motion difference based on the fusion mass at the adjacent levels was at most 3 %. All instrumentation cases generated a 55 % higher facet contact force at the lower adjacent level (L4-L5) compared to that of the intact model during 26 degrees extension and the largest increment was detected at the upper adjacent level (L2-L3) in the Ti + IS. Instrumentation with Ti + IS markedly increased the stress in the intervertebral disk at the upper adjacent level, while the stress with PEEK + IS appeared largest at the lower adjacent level. Conclusions Posterior instrumentation with semi-rigid rods may lower the incidence of disk and facet degeneration in the upper adjacent segment compared to rigid rods. On the other hand, the possibility of facet degeneration will be similar for all instrumentation devices in the lower adjacent segment in the long-term. The stiffness difference between rigid and semi-rigid rods on the changes in the adjacent motion segments was more crucial than amount of fusion mass.
引用
收藏
页码:1066 / 1077
页数:12
相关论文
共 36 条
[1]
Evaluation of the mobility of adjacent segments after posterior thoracolumbar fixation: a biomechanical study [J].
Bastian, L ;
Lange, U ;
Knop, C ;
Tusch, G ;
Blauth, M .
EUROPEAN SPINE JOURNAL, 2001, 10 (04) :295-300
[2]
BRINKELEYPARSON D, 1984, SPINE, V9, P148
[3]
Adjacent segment disease following lumbar/thoracolumbar fusion with pedicle screw instrumentation - A minimum 5-year follow-up [J].
Cheh, Gene ;
Bridwell, Keith H. ;
Lenke, Lawrence G. ;
Buchowski, Jacob M. ;
Daubs, Michael D. ;
Kim, Yongjung ;
Baldus, Christy .
SPINE, 2007, 32 (20) :2253-2257
[4]
Analysis of the effect of lumbar spine fusion on the superior adjacent intervertebral disk in the presence of disk degeneration, using the three-dimensional finite element method [J].
Chosa, E ;
Goto, K ;
Totoribe, K ;
Tajima, N .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (02) :134-139
[5]
Biomechanical Effect of Constraint in Lumbar Total Disc Replacement A Study With Finite Element Analysis [J].
Chung, Sang Ki ;
Kim, Young Eun ;
Wang, Kyu-Chang .
SPINE, 2009, 34 (12) :1281-1286
[6]
Digimation Inc., 2009, DIG PREM AN COLL MAN
[7]
A non-optimized follower load path may cause considerable intervertebral rotations [J].
Dreischarf, Marcel ;
Zander, Thomas ;
Bergmann, Georg ;
Rohlmann, Antonius .
JOURNAL OF BIOMECHANICS, 2010, 43 (13) :2625-2628
[8]
Tensile properties of nondegenerate human lumbar anulus fibrosus [J].
Ebara, S ;
Iatridis, JC ;
Setton, LA ;
Foster, RJ ;
Mow, VC ;
Weidenbaum, M .
SPINE, 1996, 21 (04) :452-461
[9]
Thoracolumbar deformity arthrodesis to L5 in adults: The fate of the L5-S1 disc [J].
Edwards, CC ;
Bridwell, KH ;
Patel, A ;
Rinella, AS ;
Kim, YJ ;
Berra, A ;
Della Rocca, GJ ;
Lenke, LG .
SPINE, 2003, 28 (18) :2122-2131
[10]
COMPARISON OF RADIOGRAPHIC FINDINGS IN FUSION AND NON-FUSION PATIENTS 10 OR MORE YEARS FOLLOWING LUMBAR-DISK SURGERY [J].
FRYMOYER, JW ;
HANLEY, EN ;
HOWE, J ;
KUHLMANN, D ;
MATTERI, RE .
SPINE, 1979, 4 (05) :435-440