Accelerated coronary MRA by simultaneous acquisition of multiple 3D stacks

被引:6
作者
Manke, D [1 ]
Börnert, P [1 ]
Nehrke, K [1 ]
Nagel, E [1 ]
Dössel, O [1 ]
机构
[1] Univ Karlsruhe, Inst Biomed Engn, Karlsruhe, Germany
关键词
MRI; coronary MRA; multistack; scan efficiency; 3D; coronary angiography;
D O I
10.1002/jmri.1210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The implementation and first in vivo results of a novel coronary magnetic resonance angiography (MRA) protocol allowing simultaneous acquisition of multiple geometrically independent 3D imaging stacks are presented. Each imaging stack is acquired in a separate cardiac phase using an individual magnetization preparation and navigator-based gating and prospective motion correction. Each stack covers one of the main coronary vessels. Thus, an improvement of scan efficiency was achieved, which was used in this study to reduce total scan time at standard image quality. Experiments performed in healthy volunteers and in patients using a two-stack approach yielded a total scan time reduction of 50% with an image quality equivalent to standard single-stack coronary MRA. J. Magn. Reson. Imaging 2001;14:478-483. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:478 / 483
页数:6
相关论文
共 20 条
[1]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[2]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[3]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[4]   Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography [J].
Goldfarb, JW ;
Edelman, RR .
RADIOLOGY, 1998, 206 (03) :830-834
[5]   Quantification of in-plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification [J].
Hofman, MBM ;
Wickline, SA ;
Lorenz, CH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :568-576
[6]  
Hofman MBM, 1999, MAGN RESON MED, V41, P360, DOI 10.1002/(SICI)1522-2594(199902)41:2<360::AID-MRM21>3.0.CO
[7]  
2-C
[8]  
KIM WY, 2001, P 4 ANN SCI SESS SCM, P50
[9]   CORONARY-ARTERIES - 3-DIMENSIONAL MR-IMAGING WITH FAT SATURATION AND MAGNETIZATION TRANSFER CONTRAST [J].
LI, D ;
PASCHAL, CB ;
HAACKE, EM ;
ADLER, LP .
RADIOLOGY, 1993, 187 (02) :401-406
[10]   Prospective adaptive navigator correction for breath-hold MR coronary angiography [J].
McConnell, MV ;
Khasgiwala, VC ;
Savord, BJ ;
Chen, MH ;
Chuang, ML ;
Edelman, RR ;
Manning, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) :148-152