Influence of surface-active compounds on the response and sensitivity of cholinesterase biosensors for inhibitor determination

被引:43
作者
Evtugyn, GA
Budnikov, HC
Nikolskaya, EB
机构
关键词
cholinesterase biosensor; inhibitor determination; non-ionogenic surfactants;
D O I
10.1039/an9962101911
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The influence of non-ionogenic surfactants, i.e., Tween-20, Triton X-100 and PEG-10 000, on the response of cholinesterase-based potentiometric biosensors and their sensitivity towards reversible and irreversible inhibitors mere investigated, Acetyl-and butyrylcholinesterases were immobilized on nylon, cellulose nitrate films and tracing paper and were introduced into an assembly of potentiometric biosensors, The effect of surface-active compounds depends on the hydrophilic properties and porosity of the enzyme support material and the inhibition mechanism, In the range 0.002-0.3% m/v the surfactants show a reversible inhibiting effect on biosensor response, At lower concentrations (down to 10(-4)% m/v) the surfactants alter the analytical characteristics of reversible and irreversible inhibitor determination, The use of surface-active additives improves the biosensor selectivity in multi-component media.
引用
收藏
页码:1911 / 1915
页数:5
相关论文
共 13 条
[1]   CYANIDE DETERMINATION USING AN AMPEROMETRIC BIOSENSOR BASED ON CYTOCHROME-OXIDASE INHIBITION [J].
AMINE, A ;
ALAFANDY, M ;
KAUFFMANN, JM ;
PEKLI, MN .
ANALYTICAL CHEMISTRY, 1995, 67 (17) :2822-2827
[2]   ENZYME AMPEROMETRIC SENSOR FOR THE DETERMINATION OF CHOLINESTERASE-INHIBITORS OR ACTIVATORS [J].
BABKINA, SS ;
MEDYANTSEVA, EP ;
BUDNIKOV, HC ;
VINTER, VG .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :419-424
[3]  
BERNABEI M, 1991, BIOELECTROCH BIOENER, V26, P237
[4]   A BIOSENSOR AS WARNING DEVICE FOR THE DETECTION OF CYANIDE, CHLOROPHENOLS, ATRAZINE AND CARBAMATE PESTICIDES [J].
BESOMBES, JL ;
COSNIER, S ;
LABBE, P ;
REVERDY, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :255-263
[5]  
BRESTKIN AP, 1989, ZH ANAL KHIM, V44, P1666
[6]   AN ENZYME AMPEROMETRIC SENSOR FOR TOXICANT DETERMINATION [J].
BUDNIKOV, HC ;
MEDYANTSEVA, EP ;
BABKINA, SS .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 310 (1-2) :49-55
[7]   Electrochemical biosensors for inhibitor determination: Selectivity and sensitivity control [J].
Budnikov, HC ;
Evtugyn, GA .
ELECTROANALYSIS, 1996, 8 (8-9) :817-820
[8]   CHOLINE DERIVATIVES AND SODIUM-FLUORIDE PROTECT ACETYLCHOLINESTERASE AGAINST IRREVERSIBLE INHIBITION AND AGING BY DFP AND PARAOXON [J].
DEHLAWI, MS ;
ELDEFRAWI, AT ;
ELDEFRAWI, ME ;
ANIS, NA ;
VALDES, JJ .
JOURNAL OF BIOCHEMICAL TOXICOLOGY, 1994, 9 (05) :261-268
[9]  
DONLAN AM, 1989, ANAL LETT, V22, P1873
[10]   AMPEROMETRIC DETERMINATION OF PESTICIDES USING A BIOSENSOR BASED ON A POLISHABLE GRAPHITE-EPOXY BIOCOMPOSITE [J].
MARTORELL, D ;
CESPEDES, F ;
MARTINEZFABREGAS, E ;
ALEGRET, S .
ANALYTICA CHIMICA ACTA, 1994, 290 (03) :343-348