Operation of the negative ion-based neutral beam injection system during Large Helical Device experimental campaigns

被引:3
作者
Oka, Y [1 ]
Kaneko, O [1 ]
Takeiri, Y [1 ]
Tsumori, K [1 ]
Osakabe, M [1 ]
Ikeda, K [1 ]
Asano, E [1 ]
Kawamoto, T [1 ]
Akiyama, R [1 ]
Hamabe, M [1 ]
机构
[1] Natl Inst Fus Sci, Toki, Gifu 5095292, Japan
关键词
Large Helical Devices (LHD); neutral beam injection (NBI); tangential; tokamak;
D O I
10.1016/S0920-3796(01)00344-1
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Large Helical Device (LHD) is the only machine that relies upon negative ion-based neutral beam injection system (NBI) as the principal heating power source. Since the first injection in 1998, NBI has been used to heat over 3000 shots for 2 years. Performance has progressed step by step to reach an injection power of 4.5 MW, with beam energy up to 165 keV, and pulse lengths up to 80 s at 0.5 MW. System operating level has reached similar to 30% of the design power and similar to 65% of the H(-) design current. This tangential high-energy NBI system based on negative ions has proved to be as efficient a heating system in a helical device as in a tokamak. The ratio of injection neutral beam power to high voltage drain power (injection power efficiency) was typically about 0.3. This is a low efficiency compared to the design one. For long pulse injection beam blocking (such as observed on PLT) was encountered, but it did not limit the operation. In order to achieve the design output of 15 MW. a great R&D effort is underway on the negative ion test stand to improve the performance of 40 A 180 keV negative hydrogen ion source. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:533 / 537
页数:5
相关论文
共 13 条
[1]   Recovery of cesium in the hydrogen negative ion sources [J].
Belchenko, YI ;
Oka, Y ;
Kaneko, O ;
Takeiri, Y ;
Krivenko, AS ;
Osakabe, M ;
Tsumori, K ;
Asano, E ;
Kawamoto, T ;
Akiyama, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02) :741-743
[2]  
EUBANK H, 1979, PLASMA PHYS CONTROLL, V1, P167
[3]   Plasma confinement studies in LHD [J].
Fujiwara, M ;
Yamada, H ;
Ejiri, A ;
Emoto, M ;
Funaba, H ;
Goto, M ;
Ida, K ;
Idei, H ;
Inagaki, S ;
Kado, S ;
Kaneko, O ;
Kawahata, K ;
Kobuchi, T ;
Komori, A ;
Kubo, S ;
Kumazawa, R ;
Masuzaki, S ;
Minami, T ;
Miyazawa, J ;
Morisaki, T ;
Morita, S ;
Murakami, S ;
Muto, S ;
Mutoh, T ;
Nagayama, Y ;
Nakamura, Y ;
Nakanishi, H ;
Narihara, K ;
Nishimura, K ;
Noda, N ;
Ohdachi, S ;
Ohyabu, N ;
Oka, Y ;
Osakabe, M ;
Ozaki, T ;
Peterson, BJ ;
Sagara, A ;
Sakakibara, S ;
Sakamoto, R ;
Sasao, H ;
Sasao, M ;
Sato, K ;
Sato, M ;
Seki, T ;
Shimozuma, T ;
Shoji, M ;
Suzuki, H ;
Takeiri, Y ;
Tanaka, K ;
Toi, K .
NUCLEAR FUSION, 1999, 39 (11Y) :1659-1666
[4]   Plasma startup by neutral beam injection in the Large Helical Device [J].
Kaneko, O ;
Takeiri, Y ;
Tsumori, K ;
Oka, Y ;
Osakabe, M ;
Funaba, H ;
Morita, S ;
Peterson, BJ ;
Sakakibara, S ;
Tanaka, K ;
Mutoh, T ;
Sato, M ;
Ohkubo, K ;
Komori, A ;
Yamada, H ;
Ohyabu, N ;
Kawahata, K ;
Motojima, O .
NUCLEAR FUSION, 1999, 39 (09) :1087-1091
[5]  
KURIYAMA M, 1998, P 20 S FUS TECHN, V1, P391
[6]   Initial physics achievements of large helical device experiments [J].
Motojima, O ;
Yamada, H ;
Komori, A ;
Ohyabu, N ;
Kawahata, K ;
Kaneko, O ;
Masuzaki, S ;
Ejiri, A ;
Emoto, M ;
Funaba, H ;
Goto, M ;
Ida, K ;
Idei, H ;
Inagaki, S ;
Inoue, N ;
Kado, S ;
Kubo, S ;
Kumazawa, R ;
Minami, T ;
Miyazawa, J ;
Morisaki, T ;
Morita, S ;
Murakami, S ;
Muto, S ;
Mutoh, T ;
Nagayama, Y ;
Nakamura, Y ;
Nakanishi, H ;
Narihara, K ;
Nishimura, K ;
Noda, N ;
Kobuchi, T ;
Ohdachi, S ;
Oka, Y ;
Osakabe, M ;
Ozaki, T ;
Peterson, BJ ;
Sagara, A ;
Sakakibara, S ;
Sakamoto, R ;
Sasao, H ;
Sasao, M ;
Sato, K ;
Sato, M ;
Seki, T ;
Shimozuma, T ;
Shoji, M ;
Suzuki, H ;
Takeiri, Y ;
Tanaka, K .
PHYSICS OF PLASMAS, 1999, 6 (05) :1843-1850
[7]   A 100 keV operation of a large vacuum-immersed H- ion source [J].
Oka, Y ;
Kaneko, O ;
Takeiri, Y ;
Tsumori, K ;
Ando, A ;
Asano, E ;
Akiyama, R ;
Kawamoto, T ;
Kuroda, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03) :1029-1031
[8]   Optimization of Cs deposition in the 1/3 scale hydrogen negative ion source for the large helical device-neutral beam injection system [J].
Oka, Y ;
Takeiri, Y ;
Belchenko, YI ;
Hamabe, M ;
Kaneko, O ;
Tsumori, K ;
Osakabe, M ;
Asano, E ;
Kawamoto, T ;
Akiyama, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03) :1379-1384
[9]  
OKA Y, 1998, P 20 S FUS TECHN MAR, V1, P371
[10]  
OSAKABE M, IN PRESS REV SCI INS