Monte Carlo-based inverse treatment planning

被引:49
作者
Jeraj, R [1 ]
Keall, P
机构
[1] Jozef Stefan Inst, Reactor Phys Div, Ljubljana, Slovenia
[2] Virginia Commonwealth Univ, Med Coll Virginia, Dept Radiat Oncol, Richmond, VA 23298 USA
[3] Liverpool Hosp, Canc Therapy Ctr, Liverpool, NSW, Australia
关键词
D O I
10.1088/0031-9155/44/8/303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A Monte Carlo-based inverse treatment planning system (MCI) has been developed which combines arguably the most accurate dose calculation method (Monte Carlo particle transport) with a 'guaranteed' optimization method (simulated annealing). A distribution of photons is specified in the tumour volume; they are transported using an adjoint calculation method to outside the patient surface to build up an intensity distribution. This intensity distribution is used as the initial input into an optimization algorithm. The dose distribution front each beam element From a number of fields is pre-calculated using Monte Carlo transport. Simulated annealing optimization is then used to find the weighting of each beam element, to yield the optimal dose distribution For the given criteria and constraints. MCI plans have been generated in various theoretical phantoms and patient geometries. These plans show conformation of the dose to the target volume and avoidance of critical structures. To verify the code, an experiment was performed on an anthropomorphic phantom.
引用
收藏
页码:1885 / 1896
页数:12
相关论文
共 51 条
[1]  
[Anonymous], 1993, 50 ICRU
[2]  
Bell G.I., 1970, NUCL REACTOR THEORY
[3]   Physical vs biological objectives for treatment plan optimization [J].
Bortfeld, T ;
Schlegel, W ;
Dykstra, C ;
Levegrun, S ;
Preiser, K .
RADIOTHERAPY AND ONCOLOGY, 1996, 40 (02) :185-185
[4]   DECOMPOSITION OF PENCIL BEAM KERNELS FOR FAST DOSE CALCULATIONS IN 3-DIMENSIONAL TREATMENT PLANNING [J].
BORTFELD, T ;
SCHLEGEL, W ;
RHEIN, B .
MEDICAL PHYSICS, 1993, 20 (02) :311-318
[5]   METHODS OF IMAGE-RECONSTRUCTION FROM PROJECTIONS APPLIED TO CONFORMATION RADIOTHERAPY [J].
BORTFELD, T ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1423-1434
[6]  
BORTFELD T, 1997, ESTRO WORKSH CHALL C
[7]   OPTIMIZATION OF STATIONARY AND MOVING BEAM RADIATION-THERAPY TECHNIQUES [J].
BRAHME, A .
RADIOTHERAPY AND ONCOLOGY, 1988, 12 (02) :129-140
[8]  
BREISMEISTER JR, 1997, MCNP GEN MONTE CARLO
[9]   FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION [J].
BURMAN, C ;
KUTCHER, GJ ;
EMAMI, B ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :123-135
[10]  
DEASY JO, 1996, MED PHYS, V23, P112