Gadolinium-enhanced ultrafast three-dimensional spoiled gradient-echo MR imaging of the abdominal aorta and visceral and iliac vessels

被引:34
作者
Gilfeather, M
Holland, GA
Siegelman, ES
Schanll, MD
Axel, L
Carpenter, JP
Golden, MA
机构
[1] HOSP UNIV PENN,DEPT RADIOL,PHILADELPHIA,PA 19104
[2] HOSP UNIV PENN,DEPT SURG,PHILADELPHIA,PA 19104
关键词
aorta; MR; arteries; magnetic resonance (MR); contrast enhancement; magnetic resonance; vascular studies;
D O I
10.1148/radiographics.17.2.9084082
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gadolinium-enhanced ultrafast three-dimensional (3D) spoiled gradient-echo magnetic resonance (MR) imaging is a noninvasive method for evaluating the abdominal aorta and the visceral and iliac vessels, With an enhanced gradient system, 20-48 sections can be obtained during a single 18-32-second patient breath hold, The 3D volume obtained from a single acquisition can be reformatted at a workstation and the vascular anatomy viewed in any projection and with a variety of section thicknesses, making this MR imaging technique particularly useful in the evaluation of aberrant arteries, vascular stenoses, aneurysms, and dissection flaps, Gadolinium-enhanced ultrafast 3D spoiled gradient-echo MR imaging has been used instead of or in addition to conventional contrast material-enhanced NIR angiography in patients who have chronic symptoms of mesenteric ischemia, who have abdominal aortic aneurysms, or who are at risk for iodinated contrast material-related renal dysfunction. This technique shows great promise for accurate and noninvasive evaluation of the abdominal aorta and the visceral and iliac vessels.
引用
收藏
页码:423 / 432
页数:10
相关论文
共 9 条
[1]  
CARPENTER JP, 1994, SURGERY, V116, P17
[2]   GADOLINIUM-ENHANCED MR ANGIOGRAPHY [J].
CREASY, JL ;
PRICE, RR ;
PRESBREY, T ;
GOINS, D ;
PARTAIN, CL ;
KESSLER, RM .
RADIOLOGY, 1990, 175 (01) :280-283
[3]   BREATH-HOLDING CAPABILITY OF ADULTS - IMPLICATIONS FOR SPIRAL COMPUTED-TOMOGRAPHY, FAST-ACQUISITION MAGNETIC-RESONANCE-IMAGING, AND ANGIOGRAPHY [J].
GAY, SB ;
SISTROM, CL ;
HOLDER, CA ;
SURATT, PM .
INVESTIGATIVE RADIOLOGY, 1994, 29 (09) :848-851
[4]   EVALUATION OF RENAL-ARTERY STENOSIS BY MAGNETIC-RESONANCE ANGIOGRAPHY [J].
HERTZ, SM ;
HOLLAND, GA ;
BAUM, RA ;
HASKAL, ZJ ;
CARPENTER, JP .
AMERICAN JOURNAL OF SURGERY, 1994, 168 (02) :140-143
[5]   Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries [J].
Holland, GA ;
Dougherty, L ;
Carpenter, JP ;
Golden, MA ;
Gilfeather, M ;
Slossman, F ;
Schnall, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (04) :971-981
[6]  
HOLLAND GA, 1995, JVIR, V6, P4
[7]   ABDOMINAL-AORTA AND RENAL-ARTERY STENOSIS - EVALUATION WITH MR ANGIOGRAPHY [J].
KIM, D ;
EDELMAN, RR ;
KENT, KC ;
PORTER, DH ;
SKILLMAN, JJ .
RADIOLOGY, 1990, 174 (03) :727-731
[8]   BREATH-HOLD GADOLINIUM-ENHANCED MR-ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND ITS MAJOR BRANCHES [J].
PRINCE, MR ;
NARASIMHAM, DL ;
STANLEY, JC ;
CHENEVERT, TL ;
WILLIAMS, DM ;
MARX, V ;
CHO, KJ .
RADIOLOGY, 1995, 197 (03) :785-792
[9]   GADOLINIUM-ENHANCED MR AORTOGRAPHY [J].
PRINCE, MR .
RADIOLOGY, 1994, 191 (01) :155-164