Resistive Polymer Versus Forced-Air Warming: Comparable Heat Transfer and Core Rewarming Rates in Volunteers

被引:34
作者
Kimberger, Oliver [1 ]
Held, Christine [1 ]
Stadelmann, Karin [1 ]
Mayer, Nikolaus [2 ]
Hunkeler, Corinne [1 ]
Sessler, Daniel I. [3 ]
Kurz, Andrea [3 ]
机构
[1] Univ Hosp Bern, Dept Anesthesiol & Pain Therapy, CH-3010 Bern, Switzerland
[2] Med Univ Vienna, Dept Anesthesiol Gen Intens Care & Pain Med, Vienna, Austria
[3] Cleveland Clin, Dept Outcomes Res, Cleveland, OH 44106 USA
关键词
D O I
10.1213/ane.0b013e3181845502
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Mild perioperative hypothermia increases the risk of several severe complications. Perioperative patient warming to preserve normothermia has thus become routine, with forced-air warming being used most often. In previous studies various resistive warming systems have shown mixed results in comparison with forced-air. Recently, a polymer-based resistive patient warming system has been developed. We compared the efficacy of a standard forced-air warming system with the resistive polymer system in volunteers. METHODS: Eight healthy volunteers participated, each on two separate study days. Unanesthetized volunteers were cooled to a core temperature (tympanic membrane) of 34 degrees C by application of forced-air at 10 degrees C and a circulating-water mattress at 4 degrees C. Meperidine and buspirone were administered to prevent shivering. In a randomly designated order, volunteers were then rewarmed (until their core temperatures reached 36 degrees C with one of the following active warming systems: (1) forced-air warming (Bair Hugger warming cover #300, blower #750, Arizant, Eden Prairie, MN); or (2) polymer fiber resistive warming (HotDog whole body blanket, HotDog standard controller, Augustine Biomedical, Eden Prairie, MN). The alternate system was used on the second study day. Metabolic heat production, cutaneous heat loss, and core temperature were measured. RESULTS: Metabolic heat production and cutaneous heat loss were similar with each system. After a 30-min delay, core temperature increased nearly linearly by 0.98 (95% confidence interval 0.91-1.04)degrees C/h with forced-air and by 0.92 (0.85-1.00)degrees C/h with resistive heating (P = 0.4). CONCLUSIONS: Heating efficacy and core rewarming rates were similar with fullbody forced-air and full-body resistive polymer heating in healthy volunteers.
引用
收藏
页码:1621 / 1626
页数:6
相关论文
共 37 条
[1]   PETHIDINE CLEARANCE DURING CONTINUOUS INTRAVENOUS INFUSIONS IN POSTOPERATIVE-PATIENTS [J].
AUSTIN, KL ;
STAPLETON, JV ;
MATHER, LE .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1981, 11 (01) :25-30
[2]   Convection warmers - not just hot air [J].
Avidan, MS ;
Jones, N ;
Ing, R ;
Khoosal, M ;
Lundgren, C ;
Morrell, DF .
ANAESTHESIA, 1997, 52 (11) :1073-1076
[3]   PREGNANCY TESTING IN ADOLESCENT PRESURGICAL PATIENTS [J].
AZZAM, FJ ;
KROCK, JL .
ANESTHESIA AND ANALGESIA, 1995, 81 (03) :661-661
[4]   BAIR-HUGGER FORCED-AIR WARMING MAINTAINS NORMOTHERMIA MORE EFFECTIVELY THAN THERMO-LITE INSULATION [J].
BORMS, SF ;
ENGELEN, SLE ;
HIMPE, DGA ;
SUY, MRR ;
THEUNISSEN, WJH .
JOURNAL OF CLINICAL ANESTHESIA, 1994, 6 (04) :303-307
[5]  
Bräuer A, 2007, CAN J ANAESTH, V54, P34
[6]   INVESTIGATION OF THE RELATIONSHIP BETWEEN HEAT-LOSS AND NITROGEN-EXCRETION IN ELDERLY PATIENTS UNDERGOING MAJOR ABDOMINAL-SURGERY UNDER GENERAL ANESTHETIC [J].
CARLI, F ;
CLARK, MM ;
WOOLLEN, JW .
BRITISH JOURNAL OF ANAESTHESIA, 1982, 54 (10) :1023-1029
[7]   BURNS FROM WARMING DEVICES IN ANESTHESIA - A CLOSED CLAIMS ANALYSIS [J].
CHENEY, FW ;
POSNER, KL ;
CAPLAN, RA ;
GILD, WM .
ANESTHESIOLOGY, 1994, 80 (04) :806-810
[8]   Concerns about the use of forced-air warming to facilitate intravenous cannulation: Don't "hose" the patient [J].
Dillon, Francis .
ANESTHESIA AND ANALGESIA, 2007, 104 (03) :739-740
[9]   Perioperative maintenance of normothermia reduces the incidence of morbid cardiac events - A randomized clinical trial [J].
Frank, SM ;
Fleisher, LA ;
Breslow, MJ ;
Higgins, MS ;
Olson, KF ;
Kelly, S ;
Beattie, C .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1997, 277 (14) :1127-1134
[10]  
GENDRON F, 1980, Journal of Clinical Engineering, V5, P19