Retrospective dosimetry: Preliminary use of the single aliquot regeneration (SAR) protocol for the measurement of quartz dose in young house bricks

被引:33
作者
Banerjee, D [1 ]
Botter-Jensen, L
Murray, AS
机构
[1] Riso Natl Lab, DK-4000 Roskilde, Denmark
[2] Aarhus Univ, Dept Earth Sci, Nordic Lab Luminescence Dating, DK-8000 Aarhus, Denmark
[3] Riso Natl Lab, DK-4000 Roskilde, Denmark
关键词
D O I
10.1093/oxfordjournals.rpd.a032769
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In retrospective dosimetry, the total dose absorbed by some pre-existing dosemeters, such as house bricks or tiles, is used to derive the dose to the population arising from a nuclear accident. This paper uses the newly developed SAR protocol to determine the total dose in young house bricks from the vicinity of the Chernobyl reactor site and from Roskilde, Denmark. For these samples, it is shown that high precision (similar to 1%) on the mean estimates of total dose can be achieved with similar to 20 independent measurements. The SAR total dose estimates of two Danish house bricks agree with the expected values based on their known age and confirms the absolute accuracy of the SAR method. It is concluded that a similar to 18 mGy fallout dose component can be detected on a background of similar to 100 mGy; this detection limit is controlled by uncertainties in the natural dose rare measurement rather than in the estimation of total dose.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 17 条
[1]   OPTICAL DATING - RECUPERATION AFTER BLEACHING [J].
AITKEN, MJ ;
SMITH, BW .
QUATERNARY SCIENCE REVIEWS, 1988, 7 (3-4) :387-393
[2]   Retrospective dosimetry with ceramics [J].
Bailiff, IK .
RADIATION MEASUREMENTS, 1997, 27 (5-6) :923-941
[3]  
Botter-Jensen L, 1999, RADIAT PROT DOSIM, V84, P537, DOI 10.1093/oxfordjournals.rpd.a032793
[4]  
Botter-Jensen L, 1999, RADIAT PROT DOSIM, V84, P335, DOI 10.1093/oxfordjournals.rpd.a032750
[5]  
BOTTERJENSEN L, 1992, NUCL TRACKS RAD MEAS, V20, P549
[6]   LUMINESCENCE DATING USING SINGLE ALIQUOTS - METHODS AND APPLICATIONS [J].
DULLER, GAT .
RADIATION MEASUREMENTS, 1995, 24 (03) :217-226
[7]  
DULLER GAT, 1991, NUCL TRACKS RAD MEAS, V18, P371
[8]   APPLICATION OF OPTICALLY STIMULATED LUMINESCENCE TO THE DOSIMETRY OF RECENT RADIATION EVENTS INVOLVING LOW TOTAL ABSORBED DOSES [J].
GODFREYSMITH, DI ;
HASKELL, EH .
HEALTH PHYSICS, 1993, 65 (04) :396-404
[9]   ACCIDENT DOSIMETRY USING ENVIRONMENTAL MATERIALS - THE ROLE OF THERMOLUMINESCENCE [J].
HASKELL, EH .
NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 21 (01) :87-93
[10]   Retrospective dosimetry sing the OSL-pre-dose effect in porcelain [J].
Hubner, S ;
Goksu, HY .
APPLIED RADIATION AND ISOTOPES, 1997, 48 (09) :1231-1235