Monitoring and characterisation of pulverised coal flames using digital imaging techniques

被引:91
作者
Yan, Y [1 ]
Lu, G
Colechin, M
机构
[1] Univ Greenwich, Sch Engn, Adv Instrumentat & Control Res Ctr, Chatham ME4 4TB, Kent, England
[2] Powergen UK Plc, Power Technol, Nottingham NG11 0EE, England
关键词
pulverised coal; flame; flame monitoring; digital imaging; image processing;
D O I
10.1016/S0016-2361(01)00161-2
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Quantification of physical properties of fossil fuel fired flames is becoming increasingly important to achieve in-depth understanding and subsequent optimisation of combustion processes. This paper presents investigations into the geometrical and luminous properties of pulverised coal flames using an advanced flame monitoring system. The system combines optical sensing, digital image processing and computing techniques and is designed to measure most physical parameters of a flame. Experimental trials of the system have recently been conducted on a 1 MWth coal-fired combustion test facility. The flame in the furnace was visualised continuously using the imaging system and then characterised in terms of geometrical and luminous parameters. Results obtained over a range of combustion conditions demonstrate that the system is capable of characterising the flames both qualitatively and quantitatively. The correlations between the flame parameters measured and the corresponding furnace data, including furnace load, mass flow rate of primary air and particle size, are identified and analysed. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:647 / 655
页数:9
相关论文
共 17 条
[1]  
ADAMSON EJ, 1997, PROC AMER POWER CONF, V59, P340
[2]   AN IMAGING NEURAL-NETWORK COMBUSTION CONTROL-SYSTEM FOR UTILITY BOILER APPLICATIONS [J].
ALLEN, MG ;
BUTLER, CT ;
JOHNSON, SA ;
LO, EY ;
RUSSO, F .
COMBUSTION AND FLAME, 1993, 94 (1-2) :205-214
[3]  
Borman G., 1998, COMBUSTION ENG
[4]  
Hashimoto H, 1992, ASME PUBLICATIONS, P1
[5]   Vision-based measurement of temperature distribution in a 500-kW model furnace using the two-colour method [J].
Huang, Y ;
Yan, Y ;
Riley, G .
MEASUREMENT, 2000, 28 (03) :175-183
[6]   Transient two-dimensional temperature measurement of open flames by dual-spectral image analysis [J].
Huang, Y ;
Yan, Y .
TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2000, 22 (05) :371-384
[7]   On-line flicker measurement of gaseous flames by image processing and spectral analysis [J].
Huang, YP ;
Yan, Y ;
Lu, G ;
Reed, A .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (08) :726-733
[8]   FLAME FAILURE-DETECTION AND MODERN BOILERS [J].
JONES, AR .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (10) :921-928
[9]  
LAWN CJ, 1987, PRINCIPLE COMBUSTION
[10]   An intelligent vision system for monitoring and control of combustion flames [J].
Lu, G ;
Yan, Y ;
Huang, Y ;
Reed, A .
MEASUREMENT & CONTROL, 1999, 32 (06) :164-168