Wang-Zwische Double Lumen Cannula-Toward a Percutaneous and Ambulatory Paracorporeal Artificial Lung

被引:112
作者
Wang, Dongfang [1 ]
Zhou, Xiaoqin [1 ]
Liu, Xiaojun [2 ]
Sidor, Bill [3 ]
Lynch, James [2 ]
Zwischenberger, Joseph B. [1 ]
机构
[1] Univ Kentucky, Coll Med, Dept Surg, Lexington, KY USA
[2] Univ Texas Med Branch, Dept Surg, Galveston, TX USA
[3] Avalon Labs, Rancho Dominguez, CA USA
基金
美国国家卫生研究院;
关键词
D O I
10.1097/MAT.0b013e31818c69ab
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We are developing a high performance double lumen cannula (DLC) for a minimally invasive, ambulatory and percutaneous paracorporeal artificial lung (PAL). The Wang-Zwische (W-Z) DLC was designed for percutaneous insertion into the Internal Jugular (IJ) vein with a drainage lumen open to both the superior vena cava (SVC) and the inferior vena cava (IVC) maximizing venous drainage. A separate collapsible but non-distensible membrane infusion lumen open to the right atrium (RA) achieves minimal recirculation allowing for total gas exchange. The W-Z DLC prototypes are made by a proprietary dip molding process with the "molded in" flat wire spiral stainless steel spring resulting in a flexible yet kink resistant thin wall (0.1 mm) outer cannula with one piece construction. With the ultra thin membrane infusion lumen collapsed, an introducer shaft fits tightly within the drainage lumen to facilitate insertion with placement at the SVC-RA-IVC junction. The W-Z DLC prototypes were tested while connected to a compact pump-gas exchanger circuit in three sheep (2 acute and one 15 day performance study). Insertion was simple, using standard percutaneous insertion techniques. Recirculation was as low as 2%. The 15 day performance study demonstrated our prototype 26 Fr W-Z DLC can achieve 2 L/min blood flow with minimal recirculation. The W-Z DLC design minimizes recirculation rate, maximizes flow lumen cross-sectional area, and maximizes achievable blood flow to enhance gas exchange performance allowing for one site percutaneous venovenous support. ASAIO journal 2008; 54:606-611.
引用
收藏
页码:606 / 611
页数:6
相关论文
共 27 条
[1]   MULTICENTER COMPARISON OF CONVENTIONAL VENOARTERIAL ACCESS VERSUS VENOVENOUS DOUBLE-LUMEN CATHETER ACCESS IN NEWBORN-INFANTS UNDERGOING EXTRACORPOREAL MEMBRANE-OXYGENATION [J].
ANDERSON, HL ;
SNEDECOR, SM ;
OTSU, T ;
BARTLETT, RH .
JOURNAL OF PEDIATRIC SURGERY, 1993, 28 (04) :530-535
[2]   VENOVENOUS EXTRACORPOREAL MEMBRANE-OXYGENATION (ECMO) USING A DOUBLE-LUMEN CANNULA [J].
ANDREWS, AF ;
ZWISCHENBERGER, JB ;
CILLEY, RE ;
DRAKE, KL .
ARTIFICIAL ORGANS, 1987, 11 (03) :265-268
[3]   Total extracorporeal arteriovenous carbon dioxide removal in acute respiratory failure: a phase I clinical study [J].
Conrad, SA ;
Zwischenberger, JB ;
Grier, LR ;
Alpard, SK ;
Bidani, A .
INTENSIVE CARE MEDICINE, 2001, 27 (08) :1340-1351
[4]  
Dalton Heidi J, 2003, Pediatr Crit Care Med, V4, P385, DOI 10.1097/01.PCC.0000075321.45152.B8
[5]  
DELIUS R, 1993, J THORAC CARDIOV SUR, V106, P329
[6]  
DYKES JDF, 2005, PRINCIPLES PRACTICE
[7]   Improved results treating lung allograft failure with venovenous extracorporeal membrane oxygenation [J].
Hartwig, MG ;
Appel, JZ ;
Cantu, E ;
Simsir, S ;
Lin, SS ;
Hsieh, CC ;
Walczak, R ;
Palmer, SM ;
Davis, RD .
ANNALS OF THORACIC SURGERY, 2005, 80 (05) :1872-1880
[8]  
Karmy-Jones RC, 2002, ANN THORAC SURG, V74, P1017
[9]   Paracorporeal artificial lung: Perioperative management for survival study in sheep [J].
Lick, SD ;
Deyo, DJ ;
Wang, DF ;
Witt, SA ;
Alpard, SK ;
Harper, DD ;
Zwischenberger, JB .
JOURNAL OF INVESTIGATIVE SURGERY, 2003, 16 (03) :177-184
[10]   Improved right heart function with a compliant inflow artificial lung in series with the pulmonary circulation [J].
Lick, SD ;
Zwischenberger, JB ;
Wang, DF ;
Deyo, DJ ;
Alpard, SK ;
Chambers, SD .
ANNALS OF THORACIC SURGERY, 2001, 72 (03) :899-904