Comparison of Two Linear Collectors in Solar Thermal Plants: Parabolic Trough Versus Fresnel

被引:74
作者
Giostri, A. [1 ]
Binotti, M. [1 ]
Silva, P. [1 ]
Macchi, E. [1 ]
Manzolini, G. [1 ]
机构
[1] Politecn Milan, Dipartimento Energia, I-20156 Milan, Italy
来源
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | 2013年 / 135卷 / 01期
关键词
parabolic trough; Fresnel linear concentrator; solar thermal plants simulation; ANGLE MODIFIERS; POWER-PLANT; PERFORMANCE;
D O I
10.1115/1.4006792
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Parabolic trough (PT) technology can be considered the state of the art for solar thermal power plants thanks to the almost 30 yr of experience gained in SEGS and, recently, Nevada Solar One plants in the United States and Andasol plant in Spain. One of the major issues that limits the wide diffusion of this technology is the high investment cost of the solar field and, particularly, of the solar collector. For this reason, research has focused on developing new solutions that aim to reduce costs. This paper compares, at nominal conditions, commercial Fresnel technology for direct steam generation with conventional parabolic trough technology based on synthetic oil as heat-transfer. The comparison addresses nominal conditions as well as annual average performance. In both technologies, no thermal storage system is considered. Performance is calculated by Thermoflex(R), a commercial code, with a dedicated component to evaluate solar plant. Results will show that, at nominal conditions, Fresnel technology has an optical efficiency of 67%, which is lower than the 75% efficiency of the parabolic trough. Calculated net electric efficiency is about 19.25%, whereas PT technology achieves 23.6% efficiency. In off-design conditions, the performance gap between Fresnel and parabolic trough increases because the former is significantly affected by high incident angles of solar radiation. The calculated sun-to-electric annual average efficiency for a Fresnel plant is 10.2%, which is a consequence of the average optical efficiency of 38.8%; a parabolic trough achieves an overall efficiency of 16%, with an optical efficiency of 52.7%. An additional case with a Fresnel collector and synthetic-oil outlines the differences among the cases investigated. Since part of the performance difference between Fresnel and PT technologies is simply due to different definitions, we introduce additional indexes to make a consistent comparison. Finally, a simplified economic assessment shows that Fresnel collectors must reduce investment costs of at least 45% than parabolic trough to achieve the same levelized cost of electricity. [DOI: 10.1115/1.4006792]
引用
收藏
页数:9
相关论文
共 26 条
[1]  
[Anonymous], 2002, P 11 INT S CONC SOL
[2]  
[Anonymous], 2006, NRELSR55040165
[3]  
Bellintani S., 2009, COMMUNICATION
[4]  
Biosol Novatech, 2009, TECHN DAT NOVA 1
[5]  
Cohen G., 2010, ASES C PHOEN
[6]  
COHEN GE, 1999, SAND991290 SANDIA
[7]  
Dersh J., 2009, P SOL PAC 2009 BERL
[8]  
Duffie J.A., 1991, Solar Engineering of Thermal Processes, Vsecond
[9]   Parabolic-trough solar collectors and their applications [J].
Fernandez-Garcia, A. ;
Zarza, E. ;
Valenzuela, L. ;
Perez, M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2010, 14 (07) :1695-1721
[10]  
Franco F, 2010, P GHGT 10 INT C AMST