Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates

被引:530
作者
Hausleiter, J
Meyer, T
Hadamitzky, M
Huber, E
Zankl, M
Martinoff, S
Kastrati, A
Schömig, A
机构
[1] Klin TU Munchen, Deutsch Herzzentrum, Klin Herz & Kreislauferkrankungen, D-80636 Munich, Germany
[2] Klin TU Munchen, Deutsch Herzzentrum, Inst Radiol & Nuklearmed, D-80636 Munich, Germany
[3] GSF Forschungszentrum Umwelt & Gesundheit, Neuherberg, Germany
关键词
imaging; tomography; angiography;
D O I
10.1161/CIRCULATIONAHA.105.602490
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Multislice computed tomography angiography (CTA) is a promising technology for imaging patients with suspected coronary artery disease. Compared with 16-slice CTA, the improved spatial and temporal resolution of 64-slice CTA (0.6-versus 1.0-mm slice thickness and 330- versus 420-ms gantry rotation time) is associated with an increase in radiation dose. The objective of this retrospective investigation was to compare the estimated dose received during 16- and 64-slice CTA in daily practice and to investigate the impact of different scan protocols on dose and image quality. Methods and Results - Radiation dose was estimated for 1035 patients undergoing coronary CTA. Scanning algorithms with and without an ECG-dependent dose modulation and with a reduced tube voltage were investigated on dose estimates and image quality. In the entire patient cohort, radiation dose estimates were 6.4 +/- 1.9 and 11.0 +/- 4.1 mSv for 16- and 64- slice CTA, respectively (P < 0.01). The reduction in radiation dose estimates ranged between 37% and 40% and between 53% and 64% with the use of ECG-dependent dose modulation and with the combined use of the dose modulation and a reduced tube voltage, respectively. The reduction in dose estimates was not associated with a reduction in diagnostic image quality as assessed by the signal-to-noise ratio and by the frequency of coronary segments with diagnostic image quality. Conclusions - The increase in spatial and temporal resolution with 64- slice CTA is associated with an increased radiation dose for coronary CTA. Dose-saving algorithms are very effective in reducing radiation exposure and should be used whenever possible.
引用
收藏
页码:1305 / 1310
页数:6
相关论文
共 16 条
  • [1] Achenbach S, 2000, CIRCULATION, V102, P2823
  • [2] Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound
    Achenbach, S
    Moselewski, F
    Ropers, D
    Ferencik, M
    Hoffmann, U
    MacNeill, B
    Pohle, K
    Baum, U
    Anders, K
    Jang, I
    Daniel, WG
    Brady, TJ
    [J]. CIRCULATION, 2004, 109 (01) : 14 - 17
  • [3] Austen W G, 1975, Circulation, V51, P5
  • [4] Multi-detector row CT angiography of the brain at various kilovoltage settings
    Ertl-Wagner, BB
    Hoffmann, RT
    Bruning, R
    Herrmann, K
    Snyder, B
    Blume, JD
    Reiser, MF
    [J]. RADIOLOGY, 2004, 231 (02) : 528 - 535
  • [5] Technique factors and image quality as functions of patient weight at abdominal CT
    Huda, W
    Scalzetti, EM
    Levin, G
    [J]. RADIOLOGY, 2000, 217 (02) : 430 - 435
  • [6] Multi-detector row CT of the left atrium and pulmonary veins before radio-frequency catheter ablation for atrial fibrillation
    Lacomis, JM
    Wigginton, W
    Fuhrman, C
    Schwartzman, D
    Armfield, DR
    Pealer, KM
    [J]. RADIOGRAPHICS, 2003, 23 : S35 - S48
  • [7] Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography - A comparative study with quantitative coronary angiography and intravascular ultrasound
    Leber, AW
    Knez, A
    von Ziegler, F
    Becker, A
    Nikolaou, K
    Paul, S
    Wintersperger, B
    Reiser, M
    Becker, CR
    Steinbeck, G
    Boekstegers, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) : 147 - 154
  • [8] Performance evaluation of a multi-slice CT system
    McCollough, CH
    Zink, FE
    [J]. MEDICAL PHYSICS, 1999, 26 (11) : 2223 - 2230
  • [9] MENZEL HG, 2000, PUBLICATION EUR
  • [10] Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography
    Mollet, NR
    Cademartiri, F
    Krestin, GP
    McFadden, EP
    Arampatzis, CA
    Serruys, PW
    de Feyter, PJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (01) : 128 - 132