High-resolution EEG: on the cortical equivalent dipole layer imaging

被引:34
作者
He, B
Yao, DZ
Lian, J
机构
[1] Univ Illinois, Dept Bioengn, Chicago, IL 60607 USA
[2] Univ Illinois, Dept Elect & Comp Engn, Chicago, IL USA
基金
美国国家科学基金会;
关键词
cortical imaging; high-resolution electroencephalogram; equivalent dipole layer imaging; visual evoked potential; human brain mapping; forward problem; inverse problem;
D O I
10.1016/S1388-2457(01)00740-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Brain electrical activity is a spatio-temporally distributed process. Cortical imaging techniques have been developed to reconstruct cortical activity from the scalp electroencephalographic or magnetoencephalographic measurements. Several cortical imaging approaches, such as the epicortical potentials and a dipole layer accounting for the cortical activity. have been used to represent brain electrical activity. Methods: A closed cortical dipole layer source model is used to equivalently represent brain electrical activity. The relationship between the primary brain electrical sources and the cortical equivalent dipole layer is derived from the theory of electromagnetics. Computer simulation studies were conducted using a 3-concentric-sphere head model to validate the proposed theory. The cortical equivalent dipole layer imaging approach was tested in both computer simulation and human visual evoked potential (VEP) experiments. Results: The strength of the cortical equivalent dipole layer is shown to be proportional to the electrical potential over the same surface generated by primary electrical sources, had the outer medium been replaced by air. The proposed theory was validated by computer simulation in a discrete system. Simulation and VEP experimental studies suggest the feasibility of applying the cortical equivalent dipole layer imaging approach for brain imaging. Conclusions: The cortical equivalent dipole layer model can equivalently represent the primary brain electrical sources throughout the entire brain surrounded by the dipole layer. The strength of the cortical equivalent dipole layer clue to primary sources can be directly calculated according to the theory developed in the present study. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:227 / 235
页数:9
相关论文
共 38 条
[1]  
[Anonymous], ANAL NEUROPHYSIOLOGI
[2]  
[Anonymous], ANN PHYS CHEM, DOI DOI 10.1002/ANDP.18531650702
[3]  
Babiloni F, 2000, METHOD INFORM MED, V39, P179
[4]   High resolution EEG: A new model-dependent spatial deblurring method using a realistically-shaped MR-constructed subject's head model [J].
Babiloni, F ;
Babiloni, C ;
Carducci, F ;
Fattorini, L ;
Anello, C ;
Onorati, P ;
Urbano, A .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 102 (02) :69-80
[5]   PARADOX IN LATERALIZATION OF VISUAL EVOKED-RESPONSE [J].
BARRETT, G ;
BLUMHARDT, L ;
HALLIDAY, AM ;
HALLIDAY, E ;
KRISS, A .
NATURE, 1976, 261 (5557) :253-255
[6]   IMPROVED LOCALIZATION OF CORTICAL ACTIVITY BY COMBINING EEG AND MEG WITH MRI CORTICAL SURFACE RECONSTRUCTION - A LINEAR-APPROACH [J].
DALE, AM ;
SERENO, MI .
JOURNAL OF COGNITIVE NEUROSCIENCE, 1993, 5 (02) :162-176
[7]   On the realization of an analytic high-resolution EEG [J].
Edlinger, G ;
Wach, P ;
Pfurtscheller, G .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (06) :736-745
[8]  
ESHEL Y, 1993, THESIS TEL AVIV U
[9]   Linear and nonlinear current density reconstructions [J].
Fuchs, M ;
Wagner, M ;
Köhler, T ;
Wischmann, HA .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1999, 16 (03) :267-295
[10]   HIGH-RESOLUTION EEG - 124-CHANNEL RECORDING, SPATIAL DEBLURRING AND MRI INTEGRATION METHODS [J].
GEVINS, A ;
LE, J ;
MARTIN, NK ;
BRICKETT, P ;
DESMOND, J ;
REUTTER, B .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1994, 90 (05) :337-358