Silica gel coated with Schiff's base: Synthesis and application as an adsorbent for cadmium, copper, zinc, and nickel determination after preconcentration by flame atomic absorption spectrometry

被引:46
作者
Shemirani, F [1 ]
Mirroshandel, AA [1 ]
Salavati-Niasari, M [1 ]
Kozani, RR [1 ]
机构
[1] Univ Tehran, Fac Sci, Dept Chem, Tehran, Iran
关键词
D O I
10.1023/B:JANC.0000018964.41166.6a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the preconcentration of Cd(II), Cu(II), Zn(II), and Ni(II) is proposed using a minicolumn filled with silica gel modified by Schiff's base. The retained analytes on the ligand-coated silica gel were recovered with a small volume of HNO3 (nitric acid). The metal ions in the eluent were determined by flame atomic absorption spectrometer (FAAS). Different factors, including the pH of the sample solution, the sample volume. the amount of silica gel, eluent volume and matrix effects for preconcentration were examined. The recoveries for the analytes under optimum working conditions were higher than 95%. The relative standard deviations of the determination were 1.50, 2.10, 2.40, 3.43% for Cu(II), Cd(II), Zn(II) and Ni(II). The limits of detection (3s, n = 10) for Cd(II), Cu(II), Zn(II), and Ni(II) were found to be 3, 5, 5 and 4.7 ngL(-1). The proposed method was applied to the analysis of some natural water samples and standard reference aluminum alloy material (NBS SRM 85b).
引用
收藏
页码:228 / 233
页数:6
相关论文
共 47 条
[1]  
AKELAH A, 1990, FUNCTIONALIZED POLYM, P139
[2]   INVESTIGATION ON THE PRECONCENTRATION OF TRACE-ELEMENTS ON POLYACRYLONITRILE [J].
ARIK, N ;
TURKER, AR .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (12) :874-876
[3]   Determination of Cu, Zn, Fe, Ni and Cd by flame atomic absorption spectrophotometry after preconcentration by Escherichia coli immobilized on sepiolite [J].
Bag, H ;
Türker, AR ;
Lale, M .
TALANTA, 2000, 51 (05) :1035-1043
[4]   Determination of zinc, cadium, cobalt and nickel by flame atomic absorption spectrometry after preconcentration by poly(ethylene terephthalate) fibers grafted with methacrylic acid [J].
Bag, H ;
Türker, AR ;
Coskun, R ;
Saçak, M ;
Yigitoglu, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :1101-1108
[5]   DIRECT DETERMINATION OF NICKEL IN HEROIN AND COCAINE BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING DEUTERIUM ARC BACKGROUND CORRECTION COMBINED WITH CHEMICAL MODIFICATION [J].
BERMEJOBARRERA, P ;
MOREDAPINEIRO, A ;
MOREDAPINEIRO, J ;
BERMEJOBARRERA, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (11) :1011-1017
[6]   Determination of Cd, Co, Cu, Mn, Ni, Pb, and Zn by inductively coupled plasma mass spectroscopy or flame atomic absorption spectrometry after on-line preconcentration and solvent extraction by flow injection system [J].
Bortoli, A ;
Gerotto, M ;
Marchiori, M ;
Mariconti, F ;
Palonta, M ;
Troncon, A .
MICROCHEMICAL JOURNAL, 1996, 54 (04) :402-411
[7]   ANALYSIS OF THERMALLY AND CHEMICALLY MODIFIED SILICA-GELS BY HETEROGENEOUS GAS SOLID CHROMATOGRAPHY AND INFRARED-SPECTROSCOPY [J].
BOUDREAU, SP ;
COOPER, WT .
ANALYTICAL CHEMISTRY, 1989, 61 (01) :41-47
[8]   EFFECT OF ORGANIC-SOLVENT AND ANION TYPE ON CATION BINDING CONSTANTS WITH SILICA-GEL BOUND MACROCYCLES AND THEIR USE IN DESIGNING SELECTIVE CONCENTRATOR COLUMNS [J].
BRUENING, ML ;
MITCHELL, DM ;
BRADSHAW, JS ;
IZATT, RM ;
BRUENING, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (01) :21-24
[9]   Simultaneous determination of Cd(II), Cu(II) and Pb(II) in surface waters by solid phase extraction and flow injection analysis with spectrophotometric detection [J].
Castillo, E ;
Cortina, JL ;
Beltrán, JL ;
Prat, MD ;
Granados, M .
ANALYST, 2001, 126 (07) :1149-1153
[10]   Synthetic zeolites as sorbent material for on-line preconcentration of copper traces and its determination using flame atomic absorption spectrometry [J].
de Peña, YP ;
López, W ;
Burguera, JL ;
Burguera, M ;
Gallignani, M ;
Brunetto, R ;
Carrero, P ;
Rondon, C ;
Imbert, F .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :249-258