Fabrication of multilayer systems combining microfluidic and microoptical elements for fluorescence detection

被引:54
作者
Roulet, JC [1 ]
Völkel, R [1 ]
Herzig, HP [1 ]
Verpoorte, E [1 ]
de Rooij, NF [1 ]
Dändliker, R [1 ]
机构
[1] Univ Neuchatel, Inst Microtechnol, CH-2000 Neuchatel, Switzerland
关键词
fIuorescence detection; glass-to-glass bonding; mu TAS; refractive microlens; wet etching;
D O I
10.1109/84.967369
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the fabrication of a microchemical chip for the detection of fluorescence species in microfluidics. The microfluidic network is wet-etched in a Borofloat 33 (Pyrex) glass wafer and sealed by means of a second wafer. Unlike other similar chemical systems, the detection system is realized with the help of microfabrication techniques and directly deposited on both sides of the microchemical chip. The detection system is composed of the combination of refractive microlens arrays and chromium aperture arrays. The microfluidic channels are 60 mum wide and 25 mum deep. The utilization of elliptical microlens arrays to reduce aberration effects and the integration of an intermediate (between the two bonded wafers) aluminum aperture array are also presented. The elliptical microlenses have a major axis of 400 mum and a minor axis of 350 mum. The circular microlens diameters range from 280 to 300 mum. The apertures deposited on the outer chip surfaces are etched in a 3000-Angstrom -thick chromium layer, whereas the intermediate aperture layer is etched in a 1000-Angstrom -thick aluminum layer. The overall thickness of this microchemical system is less than 1.6 mm. The wet-etching process and new bonding procedures are discussed. Moreover, we present the successful detection of a 10-nM Cy5 solution with a signal-to-noise ratio (SNR) of 21 dB by means of this system.
引用
收藏
页码:482 / 491
页数:10
相关论文
共 35 条
  • [1] Glass-to-glass anodic bonding with standard IC technology thin films as intermediate layers
    Berthold, A
    Nicola, L
    Sarro, PM
    Vellekoop, MJ
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2000, 82 (1-3) : 224 - 228
  • [2] BRIGHT GR, 1986, APPLICATIONS FLUORES, P257
  • [3] Holographic refractive index detector for application in microchip-based separation systems
    Burggraf, N
    Krattiger, B
    de Mello, AJ
    de Rooij, NF
    Manz, A
    [J]. ANALYST, 1998, 123 (07) : 1443 - 1447
  • [4] DOGDGE A, 2000, MICRO TOTAL ANAL SYS, P407
  • [5] MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS
    FAN, ZH
    HARRISON, DJ
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (01) : 177 - 184
  • [6] Counting single chromophore molecules for ultrasensitive analysis and separations on microchip devices
    Fister, JC
    Jacobson, SC
    Davis, LM
    Ramsey, JM
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (03) : 431 - 437
  • [7] GORING R, 1999, P SOC PHOTO-OPT INS, V3878, P136
  • [8] Single-molecule detection of DNA separations in microfabricated capillary electrophoresis chips employing focused molecular streams
    Haab, BB
    Mathies, RA
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (22) : 5137 - 5145
  • [9] HERZIG HP, 1997, MICRO OPTICS ELEMENT
  • [10] LINE-ADDRESSABLE TORSIONAL MICROMIRRORS FOR LIGHT-MODULATOR ARRAYS
    JAECKLIN, VP
    LINDER, C
    DEROOIJ, NF
    MORET, JM
    VUILLEUMIER, R
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1994, 41 (1-3) : 324 - 329