Prophylaxis against fat and bone-marrow embolism during total hip arthroplasty reduces the incidence of postoperative deep-vein thrombosis - A controlled, randomized clinical trial

被引:49
作者
Pitto, RP
Hamer, H
Fabiani, R
Radespiel-Troeger, M
Koessler, M
机构
[1] Univ Auckland, Dept Orthopaed Surg, Middlemore Hosp, Auckland 1, New Zealand
[2] Univ Erlangen Nurnberg, Dept Internal Med, Waldkrankenhaus, D-91054 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, Waldkrankenhaus, D-91054 Erlangen, Germany
[4] Univ Erlangen Nurnberg, Dept Anesthesiol & Intens Care, Waldkrankenhaus, D-91054 Erlangen, Germany
关键词
D O I
10.2106/00004623-200201000-00007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Clinical and experimental studies have suggested that the maximum risk of thrombogenesis occurs during, rather than after, total hip arthroplasty. With use of conventional cementing techniques, insertion of a femoral component results in marrow embolization of tissue thromboplastin into the veins of the proximal part of the femur, leading to activation of the clotting cascade and thrombogenesis. We hypothesized that an operative technique designed for the prevention of fat and bone-marrow embolism can also reduce the incidence of postoperative deep-vein thrombosis and pulmonary embolism. Methods: A total of 130 consecutive patients with osteoarthritis who were to have a primary total hip arthroplasty were randomly assigned to one of two groups. One group consisted of sixty-five patients (sixty-five hips) who had the femoral component inserted with our standard cementing technique without use of a bone vacuum, and the other group included sixty-five patients (sixty-five hips) who had the femoral component cemented with use of a bone-vacuum technique. In the hips managed with the bone vacuum, suction (-800 mbar) was applied to a drainage cannula placed along the linea aspera of the femur in order to prevent an increase in intramedullary pressure during the insertion of the stem. We measured the incidence of intraoperative fat and bone-marrow embolism with use of echocardiography and a transesophageal probe and the incidence of deep-vein thrombosis with use of serial duplex ultrasonography on the day before the operation and on postoperative days 4, 14, and 45. All patients were managed with prolonged pharmacological prophylaxis (low-molecular-weight heparin) against deep-vein thrombosis. Results: The control group had significantly more severe and prolonged echocardiographic embolic events than did the group managed with the bone-vacuum technique (p < 0.05). A cascade of fine echogenic particles or embolic masses with a diameter of less than or equal to5 mm was observed during the insertion of the stem in fifty-nine hips (91%) in which our standard cementing technique was used and in ten hips (15%) in which the bone-vacuum cementing technique was used. Deep-vein thrombosis was detected on postoperative day 4 in twelve patients (18%) in the control group and in two patients (3%) in the group managed with the bone-vacuum technique; the difference was significant (p < 0.05). Conclusions: Intraoperative prophylaxis against fat and bone-marrow embolism during total hip arthroplasty with cement can reduce the incidence of postoperative deep-vein thrombosis. We now use the bone-vacuum technique routinely in all total hip arthroplasties performed with cement.
引用
收藏
页码:39 / 48
页数:10
相关论文
共 52 条
[1]   Color Doppler imaging versus phlebography in the diagnosis of deep leg and pelvic vein thrombosis [J].
Becker, D ;
Gunter, E ;
Strauss, R ;
Cidlinsky, K ;
Tomandl, B ;
KaldenNemeth, D ;
Neureiter, D ;
Lang, W ;
Hahn, EG .
JOURNAL OF ULTRASOUND IN MEDICINE, 1997, 16 (01) :31-37
[2]   Low-molecular-weight heparin (enoxaparin) as prophylaxis against venous thromboembolism after total hip replacement [J].
Bergqvist, D ;
Benoni, G ;
Bjorgell, O ;
Fredin, H ;
Hedlundh, U ;
Nicolas, S ;
Nilsson, P ;
Nylander, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (10) :696-700
[3]  
BINNS M, 1990, CLIN ORTHOP RELAT R, V255, P168
[4]   ACTIVATION OF CASCADE SYSTEMS BY HIP-ARTHROPLASTY - NO DIFFERENCE BETWEEN FIXATION WITH AND WITHOUT CEMENT [J].
BREDBACKA, S ;
ANDREEN, M ;
BLOMBACK, M ;
WYKMAN, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03) :231-235
[5]  
BREED AL, 1974, CLIN ORTHOP RELAT R, V102, P227
[6]  
BROOKES M, 1971, BLOOD SUPPLY BONE, P191
[7]   RISKS OF TOTAL HIP-REPLACEMENT [J].
CHARNLEY, J .
BRITISH MEDICAL JOURNAL, 1975, 4 (5988) :101-101
[8]   ECHOCARDIOGRAPHY OF TRANSATRIAL EMBOLISM DURING CEMENTED AND UNCEMENTED HEMIARTHROPLASTY OF THE HIP [J].
CHRISTIE, J ;
BURNETT, R ;
POTTS, HR ;
PELL, ACH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03) :409-412
[9]   Cement as a risk factor for deep-vein thrombosis - Comparison of cemented TKR, uncemented TKR and cemented THR [J].
Clarke, MT ;
Green, JS ;
Harper, WM ;
Gregg, PJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (04) :611-613
[10]   Comparison of enoxaparin and warfarin for the prevention of venous thromboembolic disease after total hip arthroplasty - Evaluation during hospitalization and three months after discharge [J].
Colwell, CW ;
Collis, DK ;
Paulson, R ;
McCutchen, JW ;
Bigler, GT ;
Lutz, S ;
Hardwick, ME .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (07) :932-940