Performance of the vacuum ultraviolet high-resolution and high-flux beamline for chemical dynamics studies at the Advanced Light Source

被引:179
作者
Heimann, PA
Koike, M
Hsu, CW
Blank, D
Yang, XM
Suits, AG
Lee, YT
Evans, M
Ng, CY
Flaim, C
Padmore, HA
机构
[1] UNIV CALIF BERKELEY,LAWRENCE BERKELEY LAB,CTR XRAY OPT,DIV MAT SCI,BERKELEY,CA 94720
[2] UNIV CALIF BERKELEY,LAWRENCE BERKELEY LAB,DIV CHEM SCI,BERKELEY,CA 94720
[3] IOWA STATE UNIV,DEPT CHEM,AMES,IA 50011
[4] ACAD SINICA,INST ATOM & MOL SCI,TAIPEI 10764,TAIWAN
关键词
D O I
10.1063/1.1148082
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
At the Advanced Light Source an undulator beamline, with an energy range from 6 to 30 eV, has been constructed for chemical dynamics experiments. The higher harmonics of the undulator are suppressed by a novel, windowless gas filter. In one branchline high-flux, 2% bandwidth radiation is directed toward an end station for photodissociation and crossed molecular-beam experiments. A photon flux of 10(16) photon/s has been measured at this end station. In a second branchline a 6.65 m off-plane Eagle monochromator delivers narrow bandwidth radiation to an end station for photoionoization studies. At this second end station a peak flux of 3 x 10(11) was observed for 25 000 resolving power. This monochromator has achieved a resolving power of 70 000 using a 4800 grooves/mm grating, one of the highest resolving powers obtained by a vacuum ultraviolet monochromator. (C) 1997 American Institute of Physics.
引用
收藏
页码:1945 / 1951
页数:7
相关论文
共 20 条
[1]  
[Anonymous], 1985, Handbook of Optical Constants of Solids
[2]   STABILITY AND QUANTUM EFFICIENCY PERFORMANCE OF SILICON PHOTODIODE DETECTORS IN THE FAR ULTRAVIOLET [J].
CANFIELD, LR ;
KERNER, J ;
KORDE, R .
APPLIED OPTICS, 1989, 28 (18) :3940-3943
[3]   ON THE NE(2P5NS',ND') AUTOIONIZATION RESONANCES - HIGH-RESOLUTION MEASUREMENT AND QUANTUM DEFECT ANALYSIS [J].
GANZ, J ;
SIEGEL, A ;
BUSSERT, W ;
HARTH, K ;
RUF, MW ;
HOTOP, H ;
GEIGER, J ;
FINK, M .
JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1983, 16 (19) :L569-L576
[4]  
Gullikson E M, 1992, J Xray Sci Technol, V3, P283, DOI 10.3233/XST-1992-3402
[5]   CLEANING OF OPTICAL-SURFACES WITH PHOTOGENERATED REACTANTS [J].
HANSEN, RWC ;
WOLSKE, J ;
WALLACE, D ;
BISSEN, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3) :249-253
[6]  
HSU CP, UNPUB
[7]   A high resolution photoionization study of Ne and Ar: Observation of mass analyzed threshold ions using synchrotron radiation and direct current electric fields [J].
Hsu, CW ;
Lu, KT ;
Evans, M ;
Chen, YJ ;
Ng, CY ;
Heimann, P .
JOURNAL OF CHEMICAL PHYSICS, 1996, 105 (10) :3950-3961
[8]   HIGH-RESOLUTION VUV SPECTROSCOPIC FACILITY AT THE PHOTON-FACTORY [J].
ITO, K ;
NAMIOKA, T ;
MORIOKA, Y ;
SASAKI, T ;
NODA, H ;
GOTO, K ;
KATAYAMA, T ;
KOIKE, M .
APPLIED OPTICS, 1986, 25 (06) :837-847
[9]   VUV HIGH-RESOLUTION AND HIGH-FLUX BEAMLINE FOR CHEMICAL-DYNAMICS STUDIES AT THE ADVANCED LIGHT-SOURCE [J].
KOIKE, M ;
HEIMANN, PA ;
KUNG, AH ;
NAMIOKA, T ;
DIGENNARO, R ;
GEE, B ;
YU, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3) :282-286
[10]   Design of a high-resolution step-and-scan type monochromator capable of tuning to undulator radiation over a wavelength range of 80-180nm [J].
Koike, M ;
Heimann, PA ;
Namioka, T .
OPTICS FOR HIGH-BRIGHTNESS SYNCHROTRON RADIATION BEAMLINES II, 1996, 2856 :300-306