Tripled semitendinosus-cancellous bone anterior cruciate ligament reconstruction with bioscrew fixation

被引:31
作者
Barber, FA [1 ]
机构
[1] Plano Orthoped & Sports Med Ctr, Plano, TX 75093 USA
关键词
ACL; semitendinosus; interference fixation; bioscrew;
D O I
10.1016/S0749-8063(99)70052-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A prospective evaluation of a tripled semitendinosus-autologous cancellous bone plug ACL reconstruction, secured with bioabsorbable interference screws (Bioscrew; Linvatec, Large, FL) made of polyL-lactic acid, was undertaken from July 1994 through August 1995. A total of 21 patients with 22 anterior cruciate ligament (ACL) reconstructions were followed-up an average 29 months (range, 20 to 45). The average age was 38 years (range, 24 to 48 years). Tegner and Lysholm scores were 2.1 and 46, respectively, preoperatively and increased postoperatively to 4.4 and 90. KT tests at 24 months follow-up showed an average 20-lb laxity of 1.4 mm, an average 30-lb laxity of 2.1 mm, and an average KT maximum manual side-to-side difference of 2.9 mm. A pivot shift was absent in all but two patients at final follow-up. Full extension was rapidly achieved in all cases and flexion averaged 135 degrees at follow-up. No problems with the poly L-lactic acid interference screws occurred. These data support the effectiveness of Bioscrew fixation of the tripled semitendinosus-cancellous bone graft ACL reconstruction, which achieves both anatomic graft position and anatomic graft fixation.
引用
收藏
页码:360 / 367
页数:8
相关论文
共 22 条
[1]  
ALM A, 1974, ACTA CHIR SCAND, V140, P289
[2]   PRELIMINARY-RESULTS OF AN ABSORBABLE INTERFERENCE SCREW [J].
BARBER, FA ;
ELROD, BF ;
MCGUIRE, DA ;
PAULOS, LE .
ARTHROSCOPY, 1995, 11 (05) :537-548
[3]   Analysis of a semitendinosus autograft in a rabbit model [J].
Blickenstaff, KR ;
Grana, WA ;
Egle, D .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1997, 25 (04) :554-559
[4]   OSTEOLYTIC CHANGES ACCOMPANYING DEGRADATION OF ABSORBABLE FRACTURE FIXATION IMPLANTS [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :679-682
[5]   INTENSE GRANULOMATOUS INFLAMMATORY LESIONS ASSOCIATED WITH ABSORBABLE INTERNAL-FIXATION DEVICES MADE OF POLYGLYCOLIDE IN ANKLE FRACTURES [J].
BOSTMAN, OM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (278) :193-199
[6]  
BROSTROM L, 1968, LAKARTIDNINGEN, V64, P4477
[7]   ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING 1/3 OF THE PATELLAR LIGAMENT, AUGMENTED BY EXTRA-ARTICULAR TENDON TRANSFERS [J].
CLANCY, WG ;
NELSON, DA ;
REIDER, B ;
NARECHANIA, RG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (03) :352-359
[8]  
Edwards D J, 1994, J Shoulder Elbow Surg, V3, P230, DOI 10.1016/S1058-2746(09)80040-2
[9]  
GILLQUIST J, 1971, INJURY, V4, P271
[10]  
HOLLINGER JO, 1986, CLIN ORTHOP RELAT R, V207, P290