Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods

被引:69
作者
Faber, TL
Vansant, JP
Pettigrew, RI
Galt, JR
Blais, M
Chatzimavroudis, G
Cooke, CD
Folks, RD
Waldrop, SM
Gurtler-Krawczynska, E
Wittry, MD
Garcia, EV
机构
[1] Emory Univ, Sch Med, Dept Radiol, Atlanta, GA 30322 USA
[2] Cleveland State Univ, Dept Chem Engn, Cleveland, OH 44115 USA
[3] St Louis Univ, Div Nucl Med, St Louis, MO 63103 USA
关键词
quantitative gated single photon emission computed tomography; ejection fraction; magnetic resonance; left ventricle;
D O I
10.1067/mnc.2001.117173
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Two methods of computing left ventricular volumes and ejection fraction (EF) from 8-frame gated perfusion single photon emission computed tomography (SPECT) were compared with each other and with magnetic resonance (MR) imaging. Methods and Results. Thirty-five subjects underwent 8-frame gated dual-isotope SPECT imaging and 12- to 16-frame gated MR imaging. Endocardial boundaries on short-axis MR images were hand traced by experts blinded to any SPECT results. Volumes and EF were computed with the use of Simpson's rule. SPECT images were analyzed for the same functional variables with the use of 2 automatic programs, Quantitative Gated SPECT (QGS) and the Emory Cardiac Toolbox (ECTb). The mean difference between MR and SPECT EF was 0.008 for ECTb and 0.08 for QGS. QGS showed a slight trend toward higher correlation for EF (r = 0.72, SE of the estimate = 0.08) than ECTb (r = 0.70, SE of the estimate = 0.09). For both SPECT methods, left ventricular volumes were similarly correlated with MR, although SPECT volumes were higher than MR values by approximately 30%. Conclusions. QGS and ECTb values of cardiac function computed from 8-frame gated perfusion SPECT correlate very well with each other and correlate well with MR. Averaged over all subjects, ECTb measurements of EF are not significantly different from MR values but QGS significantly underestimates the MR values.
引用
收藏
页码:645 / 651
页数:7
相关论文
共 16 条
  • [1] Reproducibility of left ventricular size, shape and mass with echocardiography, magnetic resonance imaging and radionuclide angiography in patients with anterior wall infarction
    Baur, LHB
    Schipperheyn, JJ
    vanderVelde, EA
    vanderWall, EE
    Reiber, JHC
    vanderGeest, RJ
    vanDijkman, PRM
    Gerritsen, JG
    vanEckSmit, BLF
    Voogd, PJ
    Bruschke, AVG
    [J]. INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1996, 12 (04): : 233 - 240
  • [2] Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy
    Bax, JJ
    Lamb, H
    Dibbets, P
    Pelikan, H
    Boersma, E
    Viergever, EP
    Germano, G
    Vliegen, HW
    de Roos, A
    Pauwels, EKJ
    Van der Wall, EE
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (12) : 1299 - 1305
  • [3] SIMULTANEOUS PERFUSION FUNCTION IMAGING
    BERMAN, DS
    GERMANO, G
    KIAT, H
    FRIEDMAN, J
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 1995, 2 (03) : 271 - 273
  • [4] Case James A., 1999, Journal of the American College of Cardiology, V33, p436A
  • [5] COHADE C, 2000, J NUCL MED S, V41
  • [6] COOKE CD, 1994, J NUCL MED, V35, P1185
  • [7] Faber TL, 1999, J NUCL MED, V40, P650
  • [8] EFFECTS OF MYOCARDIAL WALL THICKNESS ON SPECT QUANTIFICATION
    GALT, JR
    GARCIA, EV
    ROBBINS, WL
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (02) : 144 - 150
  • [9] GERMANO G, 1995, J NUCL MED, V36, P2138
  • [10] An automatic approach to the analysis, quantitation and review of perfusion and function from myocardial perfusion SPECT images
    Germano, G
    Kavanagh, PB
    Berman, DS
    [J]. INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1997, 13 (04): : 337 - 346