Structural behaviour of bolted moment connections in cold-formed steel beam-column sub-frames

被引:97
作者
Wong, MF [1 ]
Chung, KF [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Structural Engn, Kowloon, Hong Kong, Peoples R China
关键词
bolted moment connections; column base connection test; failure modes;
D O I
10.1016/S0143-974X(01)00044-X
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental investigation on bolted moment connections between cold-formed steel sections. A total of 20 column base connection tests and beam-column subframe tests with different connection configurations were carried out to assess the strength and stiffness of bolted moment connections between cold-formed steel sections. Among the tests, four different modes of failure were identified: Mode BFcsw: Bearing failure in section web around bolt hole Mode LTBgp: Lateral torsional buckling of gusset plate Mode FFgp: Flexural failure of gusset plate Mode FFcs: Flexural failure of connected cold-formed steel section For those connections failed in Mode BFcsw, the moment resistances of the connections were typically found to be below 50% of the moment capacities of the connected sections. For those connections failed in Modes LTBgp and FFgp, the moment resistances of the connections were found to be about 60% and 75% of the moment capacities of the connected sections. Among all, the moment resistances of those connections failed in Mode FFcs were the highest with a minimum of 85% of the moment capacities of the connected sections. Consequently, it is demonstrated that through rational design and construction, effective moment connections between cold-formed steel sections may be readily achieved. Engineers are encouraged to build light-weight low to medium rise moment frames with cold-formed steel sections. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:253 / 274
页数:22
相关论文
共 25 条