Local methylprednisolone inhibition of foreign body response to coated intracoronary stents

被引:41
作者
deScheerder, I
Wang, K
Wilczek, K
vanDorpe, J
Verbeken, E
Desmet, W
Schacht, E
Piessens, J
机构
[1] UNIV HOSP GASTHUISBERG, DEPT PATHOL, B-3000 LOUVAIN, BELGIUM
[2] STATE UNIV GHENT, DEPT ORGAN CHEM, BIOMAT RES GRP, GHENT, BELGIUM
关键词
methylprednisolone; corticosteroids; intracoronary stenting; restenosis;
D O I
10.1097/00019501-199602000-00011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background When poly(organo)phosphazene coated metallic stents are implanted into normal coronary arteries of pigs a severe histolymphocytic and fibromuscular reaction is induced. Corticosteroids possess potent anti-inflammatory and immunosuppressive effects, they have been shown to decrease migration and functional capability of the cells of inflammation and they may stabilize lysosomal cell membranes. This study aims to evaluates the feasibility and efficacy of local corticosteroid delivery by implantation of methylprednisolone loaded coronary stents into coronary arteries of pigs. Methods Tantalum balloon expandable coronary stents were coated with poly(organo)phosphazene impregnated with 5 wt% methylprednisolone. Methylprednisolone release was calculated in vitro and then randomly either a methylprednisolone loaded stent or a plain polymer-coated stent was implanted into the right coronary artery of 20 pigs. Quantitative coronary artery analysis was done before, immediately after and 6 weeks after stent implantation. The pigs were then killed and the stented arteries processed for histopathological and morphometric evaluation. Results In-vitro testing revealed that the methylprednisolone loaded stents, when incubated in physiological saline, released 96% of the drug within 24 h. Quantitative angiography of the implanted stents showed similar angiographic parameters in both treatment groups immediately after implantation, but, after 6 weeks of follow-up study the minimal luminal diameter of the stented arterial segment was considerably larger in the methylprednisolone-treated pigs than it was in the control pigs (2.74 +/- 0.34 versus 1.36 +/- 0.72 mm, P < 0.005) This angiographic finding was confirmed at post-mortem morphometry where the respective values for neointimal thickness were 0.99 +/- 0.28 and 1.74 +/- 0.84 mm (P < 0.02). Conclusions Polymer coated stents can be loaded with methylprednisolone which inhibits the severe foreign-body reaction induced by the combination of overstretch injury and the poly(organo) phosphazene polymer coating of metallic stents.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 13 条
  • [1] BARTH K, 1989, COMPUTER ASSISTED RA, P220
  • [2] EFFICACY OF CORTICOSTEROIDS IN SUPPRESSION OF INTIMAL HYPERPLASIA
    CHERVU, A
    MOORE, WS
    QUINONESBALDRICH, WJ
    HENDERSON, T
    [J]. JOURNAL OF VASCULAR SURGERY, 1989, 10 (02) : 129 - 134
  • [3] DEGRADABLE POLYPHOSPHAZENES FOR BIOMEDICAL APPLICATIONS
    CROMMEN, J
    VANDORPE, J
    SCHACHT, E
    [J]. JOURNAL OF CONTROLLED RELEASE, 1993, 24 (1-3) : 167 - 180
  • [4] DESCHEERDER I, 1996, UNPUB CATH CARDIOVAS
  • [5] BIOCOMPATIBILITY OF POLYMER-COATED OVERSIZED METALLIC STENTS IMPLANTED IN NORMAL PORCINE CORONARY-ARTERIES
    DESCHEERDER, IK
    WILCZEK, KL
    VERBEKEN, EV
    VANDORPE, J
    LAN, PN
    SCHACHT, E
    DEGEEST, H
    PIESSENS, J
    [J]. ATHEROSCLEROSIS, 1995, 114 (01) : 105 - 114
  • [6] Desmet W, 1993, Int J Card Imaging, V9, P249, DOI 10.1007/BF01137151
  • [7] GLUCOCORTICOSTEROID THERAPY - MECHANISMS OF ACTION AND CLINICAL CONSIDERATIONS
    FAUCI, AS
    DALE, DC
    BALOW, JE
    [J]. ANNALS OF INTERNAL MEDICINE, 1976, 84 (03) : 304 - 315
  • [8] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [9] GORDON JB, 1987, CIRCULATION, V76, P213
  • [10] CORONARY INTIMAL PROLIFERATION AFTER BALLOON INJURY AND STENTING IN SWINE - AN ANIMAL-MODEL OF RESTENOSIS
    KARAS, SP
    GRAVANIS, MB
    SANTOIAN, EC
    ROBINSON, KA
    ANDERBERG, KA
    KING, SB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) : 467 - 474