A novel two-mode MPPT control algorithm based on comparative study of existing algorithms

被引:145
作者
Yu, GJ
Jung, YS
Choi, JY
Kim, GS
机构
[1] Kwangwoon Univ, Dept Elect Engn, Taejon 139701, South Korea
[2] Korea Inst Energy Ress, Photovolta Res Ctr, Taejon 305343, South Korea
[3] Seoul Natl Univ, Dept Elect & Comp Engn, Seoul 130743, South Korea
关键词
D O I
10.1016/j.solener.2003.08.038
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, the effectiveness of these three different control algorithms is thoroughly investigated via simulation and a proposed efficiency evaluation method of experimentation. Both the steady-state and transient characteristics of each control algorithms along with its measured efficiency are analyzed. Finally, a novel two-mode maximum power point tracking (MPPT) control algorithm combining the modified constant voltage control and IncCond method is proposed to improve the efficiency of the 3 kW PV power generation system at different insolation conditions. Finally, a novel two-mode MPPT control algorithm combining the modified constant voltage control and IncCond method is proposed to improve the efficiency of the 3 kW PV power generation system at different insolation conditions. Experimental results show that the proposed two-mode MPPT control provides excellent performance at less than 30% insolation intensity, covering the whole insolation area without additional hardware circuitry. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:455 / 463
页数:9
相关论文
共 3 条
[1]  
Angrist S. W., 1971, DIRECT ENERGY CONVER, P190
[2]  
Hua CC, 1998, IEEE POWER ELECTRON, P86, DOI 10.1109/PESC.1998.701883
[3]  
SULLIVAN CR, 1993, IEEE POWER ELECTRON, P574, DOI 10.1109/PESC.1993.471984