A method to evaluate the elastic behavior of vascular stents

被引:20
作者
Berry, JL
Newman, VS
Ferrario, CM
Routh, WD
Dean, RH
机构
[1] Division of Radiologie Sciences, Bowman Gray School of Medicine, Wake Forest University, Winston-Salem, NC 27157, Medical Center Blvd.
关键词
D O I
10.1016/S1051-0443(96)72875-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To develop a simple method for determining the elastic behavior of vascular stents. MATERIALS AND METHODS: An experimental apparatus was constructed to determine the elastic behavior of four different vascular stents. Each stent was expanded within an artificial compliant vessel and was subjected to an increasing external pressure. The cross-sectional area of each stent was recorded at incremental changes in pressure. Compliance was estimated from the slope of a linear regression analysis fit to the pressure-area data in the elastic range of deformation. RESULTS: The self-expandable stents were the most compliant, and balloon-expandable stents exhibited the least compliance. The balloon-expandable stents initially deformed in an elastic manner and then yielded irrecoverably at higher pressures. CONCLUSION: A simple method has been devised that allows the elastic behavior of stents to be assessed, Quantification of stent compliance with this method is important as a predictor of stent resistance to compression in vivo.
引用
收藏
页码:381 / 385
页数:5
相关论文
共 17 条
  • [1] DEFORMATION CHARACTERISTICS OF A BIOABSORBABLE INTRAVASCULAR STENT
    AGRAWAL, CM
    CLARK, HG
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 (12) : 1020 - 1024
  • [2] EVALUATION OF POLY(L-LACTIC ACID) AS A MATERIAL FOR INTRAVASCULAR POLYMERIC STENTS
    AGRAWAL, CM
    HAAS, KF
    LEOPOLD, DA
    CLARK, HG
    [J]. BIOMATERIALS, 1992, 13 (03) : 176 - 182
  • [3] NONCORONARY ANGIOPLASTY
    BECKER, GJ
    KATZEN, BT
    DAKE, MD
    [J]. RADIOLOGY, 1989, 170 (03) : 921 - 940
  • [4] COLLAPSE OF A PALMAZ STENT IN THE SUBCLAVIAN VEIN
    BJARNASON, H
    HUNTER, DW
    CRAIN, MR
    FERRAL, H
    MILTZMILLER, SE
    WEGRYN, SA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) : 1123 - 1124
  • [5] DODAI DD, 1992, CARDIOVASC INTERVENT, V15, P306
  • [6] ELASTIC CHARACTERISTICS OF THE SELF-EXPANDING METALLIC STENTS
    FALLONE, BG
    WALLACE, S
    GIANTURCO, C
    [J]. INVESTIGATIVE RADIOLOGY, 1988, 23 (05) : 370 - 376
  • [7] STRENGTH, ELASTICITY, AND PLASTICITY OF EXPANDABLE METAL STENTS - IN-VITRO STUDIES WITH 3 TYPES OF STRESS
    FLUECKIGER, F
    STERNTHAL, H
    KLEIN, GE
    ASCHAUER, M
    SZOLAR, D
    KLEINHAPPL, G
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (05) : 745 - 750
  • [8] Fontaine A B, 1993, J Vasc Interv Radiol, V4, P749, DOI 10.1016/S1051-0443(93)71967-3
  • [9] A STUDY OF THE GEOMETRICAL AND MECHANICAL-PROPERTIES OF A SELF-EXPANDING METALLIC STENT THEORY AND EXPERIMENT
    JEDWAB, MR
    CLERC, CO
    [J]. JOURNAL OF APPLIED BIOMATERIALS, 1993, 4 (01) : 77 - 85
  • [10] THE STRECKER STENT - INDICATIONS AND RESULTS IN ILIAC AND FEMOROPOPLITEAL ARTERIES
    LIERMANN, D
    STRECKER, EP
    PETERS, J
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1992, 15 (05) : 298 - 305