Assessment of left ventricular function with 16-and 64-slice multi-detector computed tomography

被引:23
作者
Abbara, Suhny [1 ,2 ]
Chow, Benjamin J. W. [1 ,2 ,3 ]
Pena, Antonio J. [1 ,2 ]
Cury, Ricardo C. [1 ,2 ]
Hoffmann, Udo [1 ,2 ]
Nieman, Koen [1 ,2 ]
Brady, Thomas J. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Univ Ottawa, Inst Heart, Div Cardiol, Ottawa, ON K1N 6N5, Canada
关键词
left ventricular function; MDCT; echocardiography; SPECT; semi-automated MDCT data analysis;
D O I
10.1016/j.ejrad.2007.07.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Important to the risk stratification and management of cardiac patients is the assessment of left ventricular function (LVEF), thus imaging modalities which can provide both anatomical and functional data is desirable. Electrocardiographic (ECG) gated multi-detector computed tomographic (MDCT) images may provide accurate assessment of LV ejection fraction, volume and dimensions but have shown systemic errors in the past due to slow gantry rotation speed. Methods: Between May 2004 and January 2005, 306 patients underwent ECG-gated cardiac CT studies at the Massachusetts General Hospital. Patients with available CT data sets and a recent (within 3 months) ECHO and/or SPECT perfusion imaging were included in the study. ECG-gated data sets were acquired either with a 16-slice or with a 64-slice MDCT. Functional MDCT data sets were reconstructed in 10 cardiac phases (5-95%) with 1.5 mm slices. Images were processed and interpreted by two observers blinded to ECHO and SPECT results. Results: A total of 69 patients had MDCT and ECHO or SPECT within 3 months (33 had 16-slice and 36 had 64-slice MDCT). There was fair correlation between LVEF measured by 16-slice MDCT and 'ECHO or SPECT' (62 +/- 10% vs. 62 +/- 10%; r = 0.56). There was poor correlation between LVEF measured by 16-slice MDCT and ECHO (64 +/- 10% vs. 59 +/- 11%; r = 0.26) and there was good correlation between LVEF measured by 16-slice MDCT and SPECT (62 +/- 11% and 64 +/- 9%, respectively; r = 0.76). There was very good correlation between LVEF measured by 64-slice MDCT and 'ECHO or SPECT' (57 +/- 15% vs. 58 +/- 13%; r = 0.86). There was very good correlation between LVEF measured by MDCT and ECHO (56 +/- 14% vs. 54 +/- 15%; r = 0.89) and between LVEF measured by 64-slice MDCT and SPECT (60 13% and 60 14%, respectively; r = 0.90). Conclusion: The assessment of LVEF and LV dimensions with 64-slice MDCT provide values which are similar to those obtained by echocardiography and Tc-99m gated SPECT. The accuracy of the 64-slice MDCT with a gantry rotation speed of 330 ms (when compared to ECHO and SPECT) may be superior to that of the 16-slice MDCT at 420 ms gantry rotation. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 34 条
[1]   BEAT-TO-BEAT VARIATION IN ECHOCARDIOGRAPHIC MEASUREMENTS OF LEFT-VENTRICULAR DIMENSIONS AND FUNCTION [J].
BETT, JHN ;
DRYBURGH, LG .
JOURNAL OF CLINICAL ULTRASOUND, 1981, 9 (03) :119-125
[2]   THE RELATIONSHIPS AMONG VENTRICULAR ARRHYTHMIAS, LEFT-VENTRICULAR DYSFUNCTION, AND MORTALITY IN THE 2 YEARS AFTER MYOCARDIAL-INFARCTION [J].
BIGGER, JT ;
FLEISS, JL ;
KLEIGER, R ;
MILLER, JP ;
ROLNITZKY, LM .
CIRCULATION, 1984, 69 (02) :250-258
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Guidelines for the management of patients with valvular heart disease - Executive summary - A report of the American College of Cardiology American Heart Association task force on practice guidelines (committee on management of patients with valvular heart disease) [J].
Bonow, RO ;
Carabello, B ;
de Leon, AC ;
Edmunds, LH ;
Fedderly, BJ ;
Freed, MD ;
Gaasch, WH ;
McKay, CR ;
Nishimura, RA ;
O'Gara, PT ;
O'Rourke, RA ;
Rahimtoola, SH ;
Ritchie, JL ;
Cheitlin, MD ;
Eagle, KA ;
Gardner, TJ ;
Garson, A ;
Gibbons, RJ ;
Russell, RO ;
Ryan, TJ ;
Smith, SC .
CIRCULATION, 1998, 98 (18) :1949-1984
[5]   Updated imaging guidelines for nuclear cardiology procedures, part 1 [J].
DePuey, EG ;
Garcia, EV .
JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (01) :G3-G58
[6]   Estimation of left ventricular chamber and stroke volume by limited M-mode echocardiography and validation by two-dimensional and Doppler echocardiography [J].
deSimone, G ;
Devereux, RB ;
Ganau, A ;
Hahn, RT ;
Saba, PS ;
Mureddu, GF ;
Roman, MJ ;
Howard, BV .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (07) :801-807
[7]   Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography [J].
Dirksen, MS ;
Bax, JJ ;
de Roos, A ;
Jukema, JW ;
van der Geest, RJ ;
Geleijns, K ;
Boersma, E ;
van der Wall, EE ;
Lamb, HJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (10) :1157-+
[8]  
FEIGENBAUM H, 1994, ECHOCARDIOGR-J CARD, P134
[9]   Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography - Comparison with magnetic resonance imaging [J].
Grude, M ;
Juergens, KU ;
Wichter, T ;
Paul, M ;
Fallenberg, EM ;
Muller, JG ;
Heindel, W ;
Breithardt, G ;
Fischbach, R .
INVESTIGATIVE RADIOLOGY, 2003, 38 (10) :653-661
[10]   Evaluation of left ventricular dysfunction using multiphasic reconstructions of coronary multi-slice computed tomography data in patients with chronic ischemic heart disease: validation against cine magnetic resonance imaging [J].
Halliburton, SS ;
Petersilka, M ;
Schvartzman, PR ;
Obuchowski, N ;
White, RD .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2003, 19 (01) :73-83