Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial

被引:347
作者
Chauhan, SK [1 ]
Scott, RG [1 ]
Breidahl, W [1 ]
Beaver, RJ [1 ]
机构
[1] Royal Perth Hosp, Perth, WA 6008, Australia
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2004年 / 86B卷 / 03期
关键词
D O I
10.1302/0301-620X.86B3.14643
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We have compared a new technique of computer-assisted knee arthroplasty with the current conventional jig-based technique in 70 patients randomly allocated to receive either of the methods. Post-operative CT was performed according to the Perth CT Knee Arthroplasty protocol and pre- and post-operative Maquet views of the limb were taken. Intra-operative and peri-operative morbidity data were collected and blood loss measured. Post-operative CT showed a significant improvement in the alignment of the components using computer-assisted surgery in regard to femoral varus/valgus (p = 0.032), femoral rotation (p = 0.001), tibial varus/valgus (p = 0.047) tibial posterior slope (p = 0.0001), tibial rotation (p 0.011) and femorotibial mismatch (p = 0.037). Standing alignment was also improved (p 0.004) and blood loss was less (p = 0.0001). Computer-assisted surgery took longer with a mean increase of 13 minutes (p = 0.0001).
引用
收藏
页码:372 / 377
页数:6
相关论文
共 17 条
[1]   FEMORAL ROTATIONAL ALIGNMENT, BASED ON THE ANTEROPOSTERIOR AXIS, IN TOTAL KNEE ARTHROPLASTY IN A VALGUS KNEE - A TECHNICAL NOTE [J].
ARIMA, J ;
WHITESIDE, LA ;
MCCARTHY, DS ;
WHITE, SE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09) :1331-1334
[2]  
CHAUHAN SK, 2002, P 62 AUSTR ORTH ASS
[3]  
CHAUHAN SK, 2000, P 62 AUSTR ORTH ASS
[4]   THE EFFECT OF ALIGNMENT OF THE IMPLANT ON FRACTURES OF THE PATELLA AFTER CONDYLAR TOTAL KNEE ARTHROPLASTY [J].
FIGGIE, HE ;
GOLDBERG, VM ;
FIGGIE, MP ;
INGLIS, AE ;
KELLY, M ;
SOBEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (07) :1031-1039
[5]   THE INFLUENCE OF TIBIAL-PATELLOFEMORAL LOCATION ON FUNCTION OF THE KNEE IN PATIENTS WITH THE POSTERIOR STABILIZED CONDYLAR KNEE PROSTHESIS [J].
FIGGIE, HE ;
GOLDBERG, VM ;
HEIPLE, KG ;
MOLLER, HS ;
GORDON, NH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1035-1040
[6]   ICLH ARTHROPLASTY OF KNEE - 1968-1977 [J].
FREEMAN, MAR ;
TODD, RC ;
BAMERT, P ;
DAY, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1978, 60 (03) :339-344
[7]   TOTAL CONDYLAR KNEE PROSTHESIS - REPORT OF 220 CASES [J].
INSALL, J ;
SCOTT, WN ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (02) :173-180
[8]   CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714
[9]   TOTAL CONDYLAR KNEE REPLACEMENT IN PATIENTS WHO HAVE RHEUMATOID-ARTHRITIS - A 10-YEAR FOLLOW-UP-STUDY [J].
LASKIN, RS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (04) :529-535
[10]  
MEIKLE RK, 2001, Z ORTHOP IHRE GRENZG, V139, P109