Predicting composition of leg sections with anthropometry and bioelectrical impedance analysis, using magnetic resonance imaging as reference

被引:73
作者
Fuller, NJ
Hardingham, CR
Graves, M
Screaton, N
Dixon, AK
Ward, LC
Elia, M
机构
[1] MRC, Dunn Clin Nutr Ctr, Cambridge CB2 2DH, England
[2] Addenbrookes Hosp, Dept Radiol, Cambridge CB2 2QQ, England
[3] Univ Queensland, Dept Biochem, Brisbane, Qld 4072, Australia
关键词
adipose tissue; muscle;
D O I
10.1042/CS19980376
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Magnetic resonance imaging (MRI) was used to evaluate and compare with anthropometry a fundamental bioelectrical impedance analysis (BIA) method for predicting muscle and adipose tissue composition in the lower limb. Healthy volunteers (eight men and eight women), aged 41 to 62 years, with mean (S.D.) body mass indices of 28.6 (5.4) kg/m(2) and 25.1 (5.4) kg/m(2) respectively, were subjected to MRI leg scans, from which 20-cm sections of thigh and IO-cm sections of lower leg (calf) were analysed for muscle and adipose tissue content, using specifically developed software. Muscle and adipose tissue were also predicted from anthropometric measurements of circumferences and skinfold thicknesses, and by use of fundamental BIA equations involving section impedance at 50 kHz and tissue-specific resistivities. Anthropometric assessments of circumferences, cross-sectional areas and volumes for total constituent tissues matched closely MRI estimates. Muscle volume was substantially overestimated (bias: thigh, -40%; calf, -18%) and adipose tissue underestimated (bias: thigh, 43%; calf, 8%) by anthropometry, in contrast to generally better predictions by the fundamental BIA approach for muscle (bias:thigh, -12%; calf, 5%) and adipose tissue (bias:thigh, 17%; calf, -28%). However, both methods demonstrated considerable individual variability (95% limits of agreement 20-77%). In general, there was similar reproducibility for anthropometric and fundamental BIA methods in the thigh (inter-observer residual coefficient of variation for muscle 3.5% versus 3.8%), but the latter was better in the calf (inter-observer residual coefficient of variation for muscle 8.2% versus 4.5%). This study suggests that the fundamental BIA method has advantages over anthropometry for measuring lower limb tissue composition in healthy individuals.
引用
收藏
页码:647 / 657
页数:11
相关论文
共 27 条
[1]   Anisotropy of human muscle via non-invasive impedance measurements [J].
Aaron, R ;
Huang, M ;
Shiffman, CA .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (07) :1245-1262
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   DETERMINATION OF UPPER ARM MUSCLE AND FAT AREAS USING ELECTRICAL-IMPEDANCE MEASUREMENTS [J].
BROWN, BH ;
KARATZAS, T ;
NAKIELNY, R ;
CLARKE, RG .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1988, 9 (01) :47-55
[4]   THE DIELECTRIC BEHAVIOUR OF SOME TYPES OF HUMAN TISSUES AT MICROWAVE FREQUENCIES [J].
COOK, HF .
BRITISH JOURNAL OF APPLIED PHYSICS, 1951, 2 (OCT) :295-300
[5]  
DUCK FA, 1990, PHYSICAL PROPERTIES
[6]   Fitness, fatness, and the effect of training assessed by magnetic resonance imaging and skinfold-thickness measurements in healthy adolescent females [J].
Eliakim, A ;
Burke, GS ;
Cooper, DM .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1997, 66 (02) :223-231
[7]   DIELECTRIC PROPERTIES OF THE HUMAN BODY IN THE MICROWAVE REGION OF THE SPECTRUM [J].
ENGLAND, TS ;
SHARPLES, NA .
NATURE, 1949, 163 (4143) :487-488
[8]   DIELECTRIC PROPERTIES OF THE HUMAN BODY FOR WAVE-LENGTHS IN THE 1-10 CM. RANGE [J].
ENGLAND, TS .
NATURE, 1950, 166 (4220) :480-480
[9]   SARCOPENIA AND AGE-RELATED-CHANGES IN BODY-COMPOSITION AND FUNCTIONAL-CAPACITY [J].
EVANS, WJ ;
CAMPBELL, WW .
JOURNAL OF NUTRITION, 1993, 123 (02) :465-468
[10]   THE ETIOLOGY AND REVERSIBILITY OF MUSCLE DYSFUNCTION IN THE AGED [J].
FIATARONE, MA ;
EVANS, WJ .
JOURNALS OF GERONTOLOGY, 1993, 48 :77-83