Intervention based on monthly monitoring decreases hemodialysis access thrombosis

被引:116
作者
Sands, JJ [1 ]
Jabyac, PA [1 ]
Miranda, CL [1 ]
Kapsick, BJ [1 ]
机构
[1] Biomed Applicat, Wilkes Barre, PA USA
关键词
D O I
10.1097/00002480-199905000-00008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We randomized 103 patients (68 arteriovenous [AV] fistulas, 35 polytetrafluoroethylene [PTFE] grafts; mean follow-up 197 days) to monthly measurement of access flow (QAT), monthly measurement of static venous pressure (VPS), or no monthly monitoring (control patients) to determine whether access thrombosis would decrease. Patients with access flow <750 cc/min or with static venous pressure greater than or equal to 0.5 were referred for angiography and angioplasty of stenotic lesions greater than or equal to 50%. Six of sixty-two (9.7%) of monthly monitored patients (MM) developed access thrombosis vs. 9 of 41 (22%) of control patients (p < 0.05). Fewer MM patients developed thrombosis in AV fistulas (2.4% [2 of 42] vs. 15.4% [4 of 26] control patients; p < 0.05). Monthly monitored patients had fewer thrombotic episodes than control patients (19 vs. 125 per 100 patient-years; p < 0.01). Thrombosis rates were lowest in patients receiving monthly access flow measurement (5.9 [QAT] vs. 30.3 per 100 patient-years [VPS]; p < 0.05). In conclusion, intervention based on monthly access flow measurement or static venous pressure decreased hemodialysis access thrombosis. Measurement of access flow tended to result in lower thrombosis rates than after static venous pressure. We believe that monthly access flow measurement will ensure the lowest incidence of thrombosis and decrease the cost of access maintenance.
引用
收藏
页码:147 / 150
页数:4
相关论文
共 24 条
[1]  
ALTMAN SD, 1995, VASCULAR ACCESS HEMO, V5, P178
[2]  
[Anonymous], 1998, J VASC TECHNOL
[3]  
[Anonymous], ASAIO J
[4]   Predicting hemodialysis access failure with color flow Doppler ultrasound [J].
Bay, WH ;
Henry, ML ;
Lazarus, JM ;
Lew, NL ;
Ling, J ;
Lowrie, EG .
AMERICAN JOURNAL OF NEPHROLOGY, 1998, 18 (04) :296-304
[5]   UTILITY OF INTRA-ACCESS PRESSURE MONITORING IN DETECTING AND CORRECTING VENOUS OUTLET STENOSES PRIOR TO THROMBOSIS [J].
BESARAB, A ;
SULLIVAN, KL ;
ROSS, RP ;
MORITZ, MJ .
KIDNEY INTERNATIONAL, 1995, 47 (05) :1364-1373
[6]  
BESARAB A, 1997, ASAIO, V43, P543
[7]  
BESARAB A, 1992, T AM SOC ART INT ORG, V38, P519
[8]  
BESARAB A, 1996, ASAIO J, V42, P682
[9]   Pressure or flow recordings for the surveillance of hemodialysis grafts [J].
Bosman, PJ ;
Boereboom, FTJ ;
Smits, HFM ;
Eikelboom, BC ;
Koomans, HA ;
Blankestijn, PJ .
KIDNEY INTERNATIONAL, 1997, 52 (04) :1084-1088
[10]  
DEPNER TA, 1991, ASAIO J, V37, P141