Clinical physiology in respiratory intensive care .12. Heart-lung interactions: Applications in the critically ill

被引:44
作者
Fessler, HE [1 ]
机构
[1] JOHNS HOPKINS MED INST, DEPT MED, DIV PULM & CRIT CARE MED, BALTIMORE, MD 21205 USA
关键词
artificial respiration; cardiopulmonary; critical care; positive end expiratory pressure;
D O I
10.1183/09031936.97.10010226
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Since the circulatory and pulmonary systems are both driven by pressure and share space in the thorax, it is inevitable that they interact. These mechanical interactions, whilst relatively few in number, are protean in their manifestations. The circulatory system of the critically ill is often particularly susceptible to interference from respiration. Compensatory reserve is limited, ventilatory effort increased, and many critical care respiratory interventions place strain on the circulation, not seen in health. This review will examine the basic physiological mechanisms through which the pulmonary and circulatory systems interact. These mechanisms will then be applied to a variety of weaning, positive end-expiratory pressure (PEEP), and cardiopulmonary resuscitation techniques. It is hoped that this will provide the tools to understand clinical observations which would otherwise appear inexplicable.
引用
收藏
页码:226 / 237
页数:12
相关论文
共 104 条
[1]   OXYGEN COST OF BREATHING AND DIAPHRAGMATIC PRESSURE-TIME INDEX - MEASUREMENT IN PATIENTS WITH COPD DURING WEANING WITH PRESSURE SUPPORT VENTILATION [J].
ANNAT, GJ ;
VIALE, JP ;
DEREYMEZ, CP ;
BOUFFARD, YM ;
DELAFOSSE, BX ;
MOTIN, JP .
CHEST, 1990, 98 (02) :411-414
[2]   RESPIRATORY MUSCLE FATIGUE DURING CARDIOGENIC-SHOCK [J].
AUBIER, M ;
TRIPPENBACH, T ;
ROUSSOS, C .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 51 (02) :499-508
[3]  
AUBIER M, 1982, AM REV RESPIR DIS, V126, P648
[4]   MECHANISMS OF BLOOD-FLOW DURING PNEUMATIC VEST CARDIOPULMONARY-RESUSCITATION [J].
BEATTIE, C ;
GUERCI, AD ;
HALL, T ;
BORKON, AM ;
BAUMGARTNER, W ;
STUART, RS ;
PETERS, J ;
HALPERIN, H ;
ROBOTHAM, JL .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (01) :454-465
[5]  
BELOUCEF S, 1995, AM J RESP CRIT CARE, V151, pA708
[6]   TREATMENT OF SEVERE CARDIOGENIC PULMONARY-EDEMA WITH CONTINUOUS POSITIVE AIRWAY PRESSURE DELIVERED BY FACE MASK [J].
BERSTEN, AD ;
HOLT, AW ;
VEDIG, AE ;
SKOWRONSKI, GA ;
BAGGOLEY, CJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 325 (26) :1825-1830
[7]   INTERACTION BETWEEN CARDIAC CHAMBERS AND THORACIC PRESSURE IN INTACT CIRCULATION [J].
BEYAR, R ;
HAUSKNECHT, MJ ;
HALPERIN, HR ;
YIN, FCP ;
WEISFELDT, ML .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (05) :H1240-H1252
[8]   CARDIAC-OUTPUT RESPONSE TO CONTINUOUS POSITIVE AIRWAY PRESSURE IN CONGESTIVE-HEART-FAILURE [J].
BRADLEY, TD ;
HOLLOWAY, RM ;
MCLAUGHLIN, PR ;
ROSS, BL ;
WALTERS, J ;
LIU, PP .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (02) :377-382
[9]   EFFECT OF LUNG-INFLATION ON LUNG BLOOD-VOLUME AND PULMONARY VENOUS FLOW [J].
BROWER, R ;
WISE, RA ;
HASSAPOYANNES, C ;
BROMBERGERBARNEA, B ;
PERMUTT, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (03) :954-963
[10]   THE EFFECT OF THE CAROTID-SINUS BARORECEPTOR REFLEX ON BLOOD-FLOW AND VOLUME REDISTRIBUTION IN THE TOTAL SYSTEMIC VASCULAR BED OF THE DOG [J].
BRUNNER, MJ ;
SHOUKAS, AA ;
MACANESPIE, CL .
CIRCULATION RESEARCH, 1981, 48 (02) :274-285