Determination of anticholinesterase pesticides in real samples using a disposable biosensor

被引:180
作者
Palchetti, I
Cagnini, A
DelCarlo, M
Coppi, C
Mascini, M
Turner, APF
机构
[1] UNIV FLORENCE, DIPARTIMENTO SANITA PUBBL EPIDEMIOL & CHIM ANALIT, I-50121 FLORENCE, ITALY
[2] CRANFIELD UNIV, CRANFIELD BIOTECHNOL CTR, CRANFIELD MK43 0AL, BEDS, ENGLAND
[3] ARPAT, DIPARTIMENTO PROV PISTOIA, PISTOIA, ITALY
关键词
biosensors; enzymatic methods; pesticides; anticholinesterase pesticides;
D O I
10.1016/S0003-2670(96)00418-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A choline amperometric biosensor based on screen-printed electrodes was assembled and used to assess the inhibitory effect of organophosphorus and carbamic pesticides on acetylcholinesterase activity both in standard solutions and real samples, Acetylcholinesterase catalyses the cleavage of acetylcholine to choline and acetate, therefore the amount of choline measured using the biosensor is directly related to the enzyme activity. The extent of enzyme inhibition can be used as an index of the amount of anticholinesterase pesticides present. The hydrophobicity of organophosphorus and carbamic pesticides led to the evaluation of organic, water miscible solvents for use in the proposed method. Berate buffer containing 1% v/v acetonitrile was selected since it exhibited the least influence on enzyme activity from the tested solvents (acetonitrile, acetone, tetrahydrofuran and ethylacetate). Other solvents (dimethylsulfoxide and methanol) were avoided as they exhibited electrochemical interferences. An inhibition calibration curve was obtained using carbofuran, a strong inhibitor of acetylcholinesterase. The lowest detectable standard solution (mean +/-3 standard deviation of the blank) was 2 mu gl(-1) following an incubation time of 10 min. The method was then applied to real samples (fruits and vegetables) showing its suitability as a rapid screening assay (12 min per test) for the assessment of anticholinesterase pesticides, The biosensor results were compared with a standard analytical technique (gas chromatography with nitrogen phosphorus detector, GC-NPD).
引用
收藏
页码:315 / 321
页数:7
相关论文
共 17 条
  • [1] ALVAREZICAZA M, 1993, ANAL CHEM, V65, P525
  • [2] AMBRUS A, 1981, J ASSOC OFF ANA CHEM, V64, P733
  • [3] BERGVELD P, 1993, CHEM SENSORS IN VI S, V1
  • [4] ANTICHOLINESTERASE ACTIVITY MEASUREMENT BY A CHOLINE BIOSENSOR - APPLICATION IN WATER ANALYSIS
    BERNABEI, M
    CHIAVARINI, S
    CREMISINI, C
    PALLESCHI, G
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) : 265 - 271
  • [5] DISPOSABLE RUTHENIZED SCREEN-PRINTED BIOSENSORS FOR PESTICIDES MONITORING
    CAGNINI, A
    PALCHETTI, I
    LIONTI, I
    MASCINI, M
    TURNER, APF
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) : 85 - 89
  • [6] Ruthenized screen-printed choline oxidase-based biosensors for measurement of anticholinesterase activity
    Cagnini, A
    Palchetti, I
    Mascini, M
    Turner, APF
    [J]. MIKROCHIMICA ACTA, 1995, 121 (1-4) : 155 - 166
  • [7] CHEMICAL SENSORS, BIOSENSORS AND THICK-FILM TECHNOLOGY
    GALANVIDAL, CA
    MUNOZ, J
    DOMINGUEZ, C
    ALEGRET, S
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (05) : 225 - 231
  • [8] IWUOHA EI, 1993, NATO ADV SCI INST SE, V252, P245
  • [9] APPLICATION OF A CHOLINESTERASE BIOSENSOR TO SCREEN FOR ORGANOPHOSPHORUS PESTICIDES EXTRACTED FROM SOIL
    KUMARAN, S
    MORITA, M
    [J]. TALANTA, 1995, 42 (04) : 649 - 655
  • [10] ENZYME SENSORS FOR THE DETECTION OF PESTICIDES
    MARTY, JL
    MIONETTO, N
    NOGUER, T
    ORTEGA, F
    ROUX, C
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (06) : 273 - 280