Optimization of aptamer microarray technology for multiple protein targets

被引:134
作者
Cho, EJ [1 ]
Collett, JR [1 ]
Szafranska, AE [1 ]
Ellington, AD [1 ]
机构
[1] Univ Texas, Dept Chem & Biochem, Inst Cell & Mol Biol, Austin, TX 78712 USA
基金
美国国家卫生研究院;
关键词
aptamer; microarray; protein; multiplex; proteomics;
D O I
10.1016/j.aca.2005.12.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aptamer-based microarrays for the quantitation of multiple protein analytes have been developed. A multiplex aptamer microarray was generated by printing two RNA aptamers (anti-lysozyme and anti-ricin) and two DNA aptamers (anti-IgE and anti-thrombin) on to either streptavidin (SA) or neutravidin (NA)-coated glass slides. However, substantial optimization was required in order to ensure the simultaneous function of the aptamer:analyte pairs. The effects of protein labeling, assay buffer. surface coating, and immobilization chemistry and orientation were investigated. A single buffer (PBS buffer containing 5 mM MgCl2 and 0.1% Tween 20) was found to work well with all the aptamers, even though this was not the buffer originally used in their selection, while neutravidin-coated slides yielded a lower detection limit, wider detection ran.-e. and more uniform background than streptavidin-coated slides. Incubation with Cy3-labeled proteins yielded sensitive, target-specific, and dose-dependent responses to each protein. Target protein concentrations as low as 72 pg/mL (5 pM, lysozyme), 15 ng/mL (0.5 nM, ricin), 1.9 ng/mL (0.01 nM, IgE), and 170 ng/mL (5 W, thrombin) Could be detected. These results show that aptarrier arrays can potentially be used with nurnerous proteins in parallel, furthering the notion that aptamer arrays may be useful in proteomics. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 90
页数:9
相关论文
共 66 条
[1]   Toward optimized antibody microarrays:: a comparison of current microarray support materials [J].
Angenendt, P ;
Glökler, J ;
Murphy, D ;
Lehrach, H ;
Cahill, DJ .
ANALYTICAL BIOCHEMISTRY, 2002, 309 (02) :253-260
[2]   Displacement enzyme linked aptamer assay [J].
Baldrich, E ;
Acero, JL ;
Reekmans, G ;
Laureyn, W ;
O'Sullivan, CK .
ANALYTICAL CHEMISTRY, 2005, 77 (15) :4774-4784
[3]   Aptasensor development: Elucidation of critical parameters for optimal aptamer performance [J].
Baldrich, E ;
Restrepo, A ;
O'Sullivan, CK .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :7053-7063
[4]   Photoaptamer arrays applied to multiplexed proteomic analysis [J].
Bock, C ;
Coleman, M ;
Collins, B ;
Davis, J ;
Foulds, G ;
Gold, L ;
Greef, C ;
Heil, J ;
Heilig, JS ;
Hicke, B ;
Hurst, MN ;
Husar, GM ;
Miller, D ;
Ostroff, R ;
Petach, H ;
Schneider, D ;
Vant-Hull, B ;
Waugh, S ;
Weiss, A ;
Wilcox, SK ;
Zichi, D .
PROTEOMICS, 2004, 4 (03) :609-618
[5]   Exploring the new world of the genome with DNA microarrays [J].
Brown, PO ;
Botstein, D .
NATURE GENETICS, 1999, 21 (Suppl 1) :33-37
[6]   Bent pseudoknots and novel RNA inhibitors of type 1 human immunodeficiency virus (HIV-1) reverse transcriptase [J].
Burke, DH ;
Scates, L ;
Andrews, K ;
Gold, L .
JOURNAL OF MOLECULAR BIOLOGY, 1996, 264 (04) :650-666
[7]   Functional RNA microarrays for high-throughput screening of antiprotein aptamers [J].
Collett, JR ;
Cho, EJ ;
Lee, JF ;
Levy, M ;
Hood, AJ ;
Wan, C ;
Ellington, AD .
ANALYTICAL BIOCHEMISTRY, 2005, 338 (01) :113-123
[8]   Automated RNA selection [J].
Cox, JC ;
Rudolph, P ;
Ellington, AD .
BIOTECHNOLOGY PROGRESS, 1998, 14 (06) :845-850
[9]   Automated selection of anti-protein aptamers [J].
Cox, JC ;
Ellington, AD .
BIOORGANIC & MEDICINAL CHEMISTRY, 2001, 9 (10) :2525-2531
[10]   Use of a high affinity DNA ligand in flow cytometry [J].
Davis, KA ;
Abrams, B ;
Lin, Y ;
Jayasena, SD .
NUCLEIC ACIDS RESEARCH, 1996, 24 (04) :702-706