A transcutaneous energy transmission system with rechargeable internal back-up battery for a totally implantable total artificial heart

被引:13
作者
Shiba, K
Shu, EM
Koshiji, K
Tsukahara, K
Nakamura, T
Masuzawa, T
Tatsumi, E
Taenaka, Y
Takano, H
机构
[1] Tokyo Univ Sci, Koshiji Lab, Dept Elect Engn, Fac Sci & Technol, Noda, Chiba 2788510, Japan
[2] Aisin Cosmos Res & Dev Co Ltd, Aichi, Japan
[3] Natl Cardiovasc Ctr, Inst Res, Dept Artificial Organs, Osaka, Japan
关键词
D O I
10.1097/00002480-199909000-00019
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
We have been developing an externally coupled transcutaneous energy transmission system (ECTETS) for a totally implantable total artificial heart (TITAH). When the ECTETS is unable to supply the energy to drive the TITAH from outside the body, a rechargeable internal back-up battery (RIBB) implanted inside the body is used as a back-up to supply the required energy, This paper reports on the performance characteristics of our ECTETS with an RIBB. In this study, a lithium-ion (Li+) secondary battery was used as the RIBB. The transcutaneous energy transmission and the charging control characteristics of the ECTETS, while simultaneously supplying energy to the TITAH and the RIBB, were evaluated in an in vitro experiment. The output power and transmission efficiency of the ECTETS operating in this mode were found to vary from 20 W to 34 W and from 84% to 71%, respectively. It was also found that a sufficient power of more than 20 W could be supplied to the TITAH. The time needed to fully charge the RIBB was 117 minutes, and a fully charged RIBB could drive the TITAH, consuming 20 W for 62 minutes, It may, therefore, reasonably be concluded that the ECTETS with the RIBB is sufficient to drive the TITAH.
引用
收藏
页码:466 / 470
页数:5
相关论文
共 12 条
[1]
Selection of a rechargeable internal back-up battery for a totally implantable artificial heart [J].
Honda, H ;
Shiba, K ;
Shu, E ;
Koshiji, K ;
Murai, T ;
Nakamura, T ;
Masuzawa, T ;
Tatsumi, E ;
Taenaka, Y ;
Takano, H .
ASAIO JOURNAL, 1999, 45 (04) :339-343
[2]
Honda H, 1997, P ANN INT IEEE EMBS, V19, P2315, DOI 10.1109/IEMBS.1997.758827
[3]
HONDA H, 1996, P 12 ANN C SOC LIF S, P191
[4]
KOSHIJI K, 1996, JPN J ARTIF ORGANS, V25, P881
[5]
KOSHIJI K, 1989, JPN J ARTIF ORGANS, V18, P533
[6]
MASUZAWA T, 1995, ASAIO J, V41, pM249, DOI 10.1097/00002480-199507000-00005
[8]
Mitamura Y., 1996, Japanese Journal of Artificial Organs, V25, P738
[9]
MUSSIVAND T, 1995, ASAIO J, V41, pM253, DOI 10.1097/00002480-199507000-00006
[10]
Shiba K, 1997, P ANN INT IEEE EMBS, V19, P2503, DOI 10.1109/IEMBS.1997.756836