Acute and mid-term outcomes of transvenous implant of a new left ventricular quadripolar lead versus bipolar leads for cardiac resynchronization therapy: Results from a single-center prospective database

被引:17
作者
Arias, Miguel A. [1 ]
Pachon, Marta [1 ]
Puchol, Alberto [1 ]
Jimenez-Lopez, Jesus [1 ]
Rodriguez-Padial, Luis [1 ]
机构
[1] Hosp Virgen Salud, Cardiac Arrhythmia & Electrophysiol Unit, Dept Cardiol, Toledo 45004, Spain
关键词
cardiac resynchronization; left ventricular lead; heart failure; cardiac pacing; coronary sinus; PACING LEAD; STIMULATION; EXPERIENCE;
D O I
10.5603/CJ.2012.0087
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The purpose of this study was to evaluate the feasibility of the use of a quadripolar left ventricular (LV) lead for cardiac resynchronization therapy and to compare its acute and mid-term outcomes with those obtained with bipolar leads. Cardiac resynchronization exhibits a high incidence of problems involving the LV lead when conventional leads are use and these problems may be minimized by using multipolar leads. Methods: We gathered clinical, implant, and follow-up data at 3 and 9 months from 21 consecutive patients in whom a quadripolar (Group Q) or bipolar (Group B) lead was used for a biventricular defibrillator implant. Results: The leads were successfully implanted in all of the patients. In Group B, more than one lead was used in 20% (p = 0.048) of cases. There were no clinical differences or differences in the implant parameters between the two groups except for the radiation dose, which was greater in group B (p = 0.035). The incidence of problems related to the LV lead during follow-up was higher in group B, but the difference was not significant (42.9% vs. 23.8%, p = 0.326). The use of more than one LV lead was the only variable that was significantly associated with lead-related problems during follow-up = 0.03; OR = 10.8; 95% CI 1.07-108.61). Conclusions: The quadripolar lead was associated with excellent implantation success rates and mid-term performance. The multi-programmability capabilities of quadripolar leads facilitated the achievement of implant goals and helped to reduce problems during the implant and follow-up. (Cardiol J 2012; 19, 5: 470-478)
引用
收藏
页码:470 / 478
页数:9
相关论文
共 11 条
[1]   Phrenic Stimulation A Challenge for Cardiac Resynchronization Therapy [J].
Biffi, Mauro ;
Moschini, Carlotta ;
Bertini, Matteo ;
Saporito, Davide ;
Ziacchi, Matteo ;
Diemberger, Igor ;
Valzania, Cinzia ;
Domenichini, Giulia ;
Cervi, Elena ;
Martignani, Cristian ;
Sangiorgi, Diego ;
Branzi, Angelo ;
Boriani, Giuseppe .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (04) :402-410
[2]   Fluctuation of left ventricular thresholds and required safety margin for left ventricular pacing with cardiac resynchronization therapy [J].
Burri, Haran ;
Gerritse, Bart ;
Davenport, Lynn ;
Demas, Myriam ;
Sticherling, Christian .
EUROPACE, 2009, 11 (07) :931-936
[3]   The European cardiac resynchronization therapy survey [J].
Dickstein, Kenneth ;
Bogale, Nigussie ;
Priori, Silvia ;
Auricchio, Angelo ;
Cleland, John G. ;
Gitt, Anselm ;
Limbourg, Tobias ;
Linde, Cecilia ;
van Veldhuisen, Dirk J. ;
Brugada, Josep .
EUROPEAN HEART JOURNAL, 2009, 30 (20) :2450-2460
[4]   Left ventricular pacing with a new quadripolar transvenous lead for CRT: Early results of a prospective comparison with conventional implant outcomes [J].
Forleo, Giovanni B. ;
Della Rocca, Domenico G. ;
Papavasileiou, Lida P. ;
Di Molfetta, Arianna ;
Santini, Luca ;
Romeo, Francesco .
HEART RHYTHM, 2011, 8 (01) :31-37
[5]   Long-term retention of cardiac resynchronization therapy [J].
Knight, BP ;
Desai, A ;
Coman, J ;
Faddis, M ;
Yong, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (01) :72-77
[6]   Long-Term Complications Related to Biventricular Defibrillator Implantation Rate of Surgical Revisions and Impact on Survival: Insights From the Italian ClinicalService Database [J].
Landolina, Maurizio ;
Gasparini, Maurizio ;
Lunati, Maurizio ;
Iacopino, Saverio ;
Boriani, Giuseppe ;
Bonanno, Carlo ;
Vado, Antonello ;
Proclemer, Alessandro ;
Capucci, Alessandro ;
Zucchiatti, Chantal ;
Valsecchi, Sergio ;
Ricci, Renato P. ;
Santini, Massimo .
CIRCULATION, 2011, 123 (22) :2526-2535
[7]   Elimination of phrenic nerve stimulation occurring during CRT Follow-up in patients implanted with a novel quadripolar pacing lead [J].
Mehta, Paresh A. ;
Shetty, Anoop K. ;
Squirrel, Mark ;
Bostock, Julian ;
Rinaldi, C. Aldo .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 33 (01) :43-49
[8]   Use of a quadripolar left ventricular lead to achieve successful implantation in patients with previous failed attempts at cardiac resynchronization therapy [J].
Shetty, Anoop K. ;
Duckett, Simon G. ;
Bostock, Julian ;
Rosenthal, Eric ;
Rinaldi, C. Aldo .
EUROPACE, 2011, 13 (07) :992-996
[9]   Initial Single-Center Experience of a Quadripolar Pacing Lead for Cardiac Resynchronization Therapy [J].
Shetty, Anoop K. ;
Duckett, Simon G. ;
Bostock, Julian ;
Roy, Debashis ;
Ginks, Matthew ;
Hamid, Shoaib ;
Rosenthal, Eric ;
Razavi, Reza ;
Rinaldi, Christopher Aldo .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (04) :484-489
[10]   Left Ventricular Lead Position and Clinical Outcome in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) Trial [J].
Singh, Jagmeet P. ;
Klein, Helmut U. ;
Huang, David T. ;
Reek, Sven ;
Kuniss, Malte ;
Quesada, Aurelio ;
Barsheshet, Alon ;
Cannom, David ;
Goldenberg, Ilan ;
McNitt, Scott ;
Daubert, James P. ;
Zareba, Wojciech ;
Moss, Arthur J. .
CIRCULATION, 2011, 123 (11) :1159-1166