Optimized image reconstruction for detection of deep venous thrombosis at multidetector-row CT venography

被引:35
作者
Das, M
Mühlenbruch, G
Mahnken, AH
Weiss, C
Schoepf, UJ
Leidecker, C
Günther, RW
Wildberger, JE
机构
[1] Univ Technol, Rhein Westfal TH Aachen, Univ Hosp, Dept Diagnost Radiol, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Inst Med Stat, D-5100 Aachen, Germany
[3] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
[4] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
关键词
indirect venography; computed tomography; sequential; spiral dose;
D O I
10.1007/s00330-005-2868-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aims of this study were to optimize image quality for indirect CT venography (sequential versus spiral), and to evaluate different image reconstruction parameters for patients with suspected deep venous thrombosis (DVT). Fifty-one patients (26/25 with/without DVT) were prospectively evaluated for pulmonary embolism (PE) with standard multidetector-row computed tomography (MDCT) protocols. Retrospective image reconstruction was done with different slice thicknesses and reconstruction increments in sequential and spiral modes. All reconstructions were read for depiction of DVT and to evaluate best reconstruction parameters in comparison with the thinnest reconstruction ("gold standard"). Image noise and venous enhancement were measured as objective criteria for image quality. Subjective image quality was rated on a four-point scale. Effective dose was estimated for all reconstructions. In sequential 10/50 reconstruction DVT was completely detected in 13/26 cases, partially in 10/26 cases and was not detected at all in 3/26 cases, and 15/26, 9/26 and 2/26 cases for the 10/20 reconstruction, respectively. DVT was completely detected in all spiral reconstructions. Image noise ranged between 14.8-29.1 HU. Median image quality was 2. Estimated effective dose ranged between 2.3 mSv and 11.8 mSv. Gaps in sequential protocols may lead to false negative results. Therefore, spiral scanning protocols for complete depiction of DVT are mandatory.
引用
收藏
页码:269 / 275
页数:7
相关论文
共 23 条
[1]   Evaluation of the deep venous system in patients with suspected pulmonary embolism with multi-detector CT: A prospective study in comparison to Doppler sonography [J].
Begemann, PGC ;
Bonacker, M ;
Kemper, J ;
Guthoff, AE ;
Hahn, KE ;
Steiner, P ;
Adam, G .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (03) :399-409
[2]   Deep venous thrombosis: Detection by using indirect CT venography [J].
Cham, MD ;
Yankelevitz, DF ;
Shaham, D ;
Shah, AA ;
Sherman, L ;
Lewis, A ;
Rademaker, J ;
Pearson, G ;
Choi, JS ;
Wolff, W ;
Prabhu, PM ;
Galanski, M ;
Clark, RA ;
Sostman, HD ;
Henschke, CI .
RADIOLOGY, 2000, 216 (03) :744-751
[3]   Using dual-detector helical CT angiography to detect deep venous thrombosis in patients with suspicion of pulmonary embolism: Diagnostic value and additional findings [J].
Coche, EE ;
Hamoir, XL ;
Hammer, FD ;
Hainaut, P ;
Goffette, PP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (04) :1035-1039
[4]   Evaluation of the lower extremity veins in patients with suspected pulmonary embolism: A retrospective comparison of helical CT venography and sonography [J].
Duwe, KM ;
Shiau, M ;
Budorick, NE ;
Austin, JHM ;
Berkmen, YM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (06) :1525-1531
[5]   Thromboembolic disease:: Comparison of combined CT pulmonary angiography and venography with bilateral leg sonography in 70 patients [J].
Garg, K ;
Kemp, JL ;
Wojcik, D ;
Hoehn, S ;
Johnston, RJ ;
Macey, LC ;
Barón, AE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (04) :997-1001
[6]   Thromboembolic disease:: Variability of interobserver agreement in the interpretation of CT venography with CT pulmonary angiography [J].
Garg, K ;
Kemp, JL ;
Russ, PD ;
Barón, AE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (04) :1043-1047
[7]  
Ghaye B, 2000, JBR-BTR, V83, P271
[8]  
Goldhaber S Z, 2001, Semin Vasc Med, V1, P139, DOI 10.1055/s-2001-18481
[9]   Pulmonary embolism [J].
Goldhaber, SZ .
LANCET, 2004, 363 (9417) :1295-1305
[10]  
Hyers TM, 1999, AM J RESP CRIT CARE, V159, P1