High-throughput quantification for a drug mixture in rat plasma -: a comparison of Ultra PerformanceTM liquid chromatography/tandem mass spectrometry with high-performance liquid chromatography/tandem mass spectrometry

被引:100
作者
Yu, K [1 ]
Little, D
Plumb, R
Smith, B
机构
[1] Waters Corp, Milford, MA 01757 USA
[2] Waters Corp, MS Technol Ctr, Manchester, Lancs, England
关键词
D O I
10.1002/rcm.2336
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A quantitative Ultra Performance (TM) liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r(2) values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:544 / 552
页数:9
相关论文
共 28 条
[1]   Use of generic fast gradient liquid chromatography tandem mass spectroscopy in quantitative bioanalysis [J].
Ayrton, J ;
Dear, GJ ;
Leavens, WJ ;
Mallett, DN ;
Plumb, RS .
JOURNAL OF CHROMATOGRAPHY B, 1998, 709 (02) :243-254
[2]  
Ayrton J, 1999, RAPID COMMUN MASS SP, V13, P1657, DOI 10.1002/(SICI)1097-0231(19990830)13:16<1657::AID-RCM694>3.0.CO
[3]  
2-L
[4]  
Ayrton J, 1998, RAPID COMMUN MASS SP, V12, P217, DOI 10.1002/(SICI)1097-0231(19980314)12:5<217::AID-RCM146>3.0.CO
[5]  
2-I
[6]  
Ayrton J, 1997, RAPID COMMUN MASS SP, V11, P1953, DOI 10.1002/(SICI)1097-0231(199712)11:18<1953::AID-RCM102>3.0.CO
[7]  
2-Z
[8]  
Bayliss MK, 2000, RAPID COMMUN MASS SP, V14, P2039, DOI 10.1002/1097-0231(20001115)14:21<2039::AID-RCM130>3.0.CO
[9]  
2-2
[10]  
Bowers GD, 1997, LC GC-MAG SEP SCI, V15, P48